6
© 2014 - 2024 Parktron Technology Ltd.
1.2.2. Power, network cable, control signal & intercom wires:
Make sure all the following wire and cable items are properly pre-installed to foundation
island:
Electric power line (to both terminal and barrier) – PVC 2.0 mm2 / 3C.
Parking system network cable (to terminal only) – Standard CAT-5 (with RJ45
connector).
Intercom wire (to terminal only) – PVC 0.75 mm2 / 2C.
Control signal wire (from terminal to barrier) – 22AWG / 8C.
1.2.3. Anchor bolts:
For a stronger strength, pre-install embedded type anchor bolts (M16 stainless steel)
are highly recommended at the time of building the cement foundation island. Refer
to figure below for embedding dimension reference:
Or drill and install expansion type of bolts (M16 stainless steel) as below picture: