© 2014 - 2024 Parktron Technology Ltd.
© 2014 - 2024 Parktron Technology Ltd.
16
17
Title
Specification
Qty
Note
Barrier Gate Core
1
Main part
Barrier Gate Boom
Straight boom
/
Fence boom
/
Folding boom
1
According to your choice
Hexagonal Head
Tap Bolt
M8×55mm
6
For fixing the boom
Boom Press Board
1
For fixing the boom
Self
-
tapping screw
ST4×16
1
For fixing the boom
Self
-
tapping screw
ST3×10
4
For fixing the boom
Supporting pole
1
For supporting the boom
Expansion Bolt
M16×150
4
For fixing the case
Hexagonal Inner
Screw
M8×35
4
For fixing the case
Clutch Key
1
For clutch device
Case Key
2
For barrier gate case
and cove locking
Balance Spring
According to length
of the arm
1
For spare usage
Remote Emitter
Less than 30M is available
1
For remote controlling
Remote Controller
Less than 30M is available
2
For remote controlling
Instruction
1
For reference
Rs485 transition
Interface
1
Optional part
Disc
1
Optional part
Communication
Module
1
Optional part
Cover head
1
Expansion nut
M8
4
For fixing the supporting
pole
8) Common malfunctions and solutions
(1)
Motor works but there is no reaction on the arm
a. Please check whether the clutch device is locked or
not
.
(2)
There is too much vibrant when the boom is rising or
falling
.
a. Please check whether the shock absorption rubber is
broken or not
,
if yes
,
change a new one
.
b. Please check whether the balance spring is overused
and distorted
.
If yes
,
change a new one
;
or spin
bottom adjust nut
.
(3)
The boom could not rise up or fall down to the end
.
a. When change a long boom to a short one
,
please
readjust it
.
b. The sensor dose not plug well
,
please check it
.
c. The
"
Speed adjust switch
"
is wrong adjust
,
please
readjust it
.
(4)
The distance of the remote control decreases
.
a. Check whether the charge capacity of the remote
controller is enough or not
.
(5)
There is no reaction when pressing the remote controller
buttons
.
a. Please check whether the power is supplied to the
barrier gate or not
.
b. Please check whether the fuse is burnt out or not
.
c. Please check whether the code both in the remote
controller and the control board are accordant or not
.
(6)
There is no reaction on the motor when the user
changes a control board
.
a. Please check the capacitance is correctly fixed or not
.
b
.
Please check the sensor is right inserted or not
.
(7)
If the user changes a new control board and the boom is abnormal
when rising and falling
.
a. Please adjust the
"
Gate Type Selection
"(
Refer to the control board
).
9) Packing list