15
GB
11. Possible causes of failure
Problem
Cause
Solution
The compressor does not
start.
1. No supply voltage.
2. Insufficient supply voltage.
3. Outside temperature is too
low.
4. Motor is overheated.
1. Check the supply voltage,
the power plug and the
socket-outlet.
2. Make sure that the
extension cable is not too
long. Use an extension cable
with large enough wires.
3. Never operate with an
outside temperature of
below +5° C.
4. Allow the motor to cool
down. If necessary, remedy
the cause of the overheating.
The compressor starts but
there is no pressure.
1. The non-return valve leaks.
2. The seals are damaged.
3. The drain plug for
condensation water (9)
leaks.
1. Replace the non-return
valve.
2. Check the seals and have
any damaged seals replaced
by a service center.
3. Tighten the screw by hand.
Check the seal on the screw
and replace if necessary.
The compressor starts,
pressure is shown on the
pressure gauge, but the
tools do not start.
1. Loose hose connections.
2. Leak in a quick-lock
coupling.
3. Insufficient pressure set on
the pressure regulator (3).
1. Check the compressed air
hose and tools and replace if
necessary.
2. Check the quick-lock
coupling and replace if
necessary.
3. Increase the set pressure
with the pressure regulator.
Anleitung_4010363:_ 27.05.2010 17:00 Uhr Seite 15
Содержание PKO 270 A1
Страница 1: ...PKO 270 A1 LB4 Air Compressor Artikel Nr 4010363 Ident Nr 11010...
Страница 3: ......
Страница 8: ...5 10 12 13 D C D F E C 16 21 11 max min 18 Anleitung_4010363 _ 27 05 2010 17 00 Uhr Seite 5...
Страница 81: ...78 Anleitung_4010363 _ 27 05 2010 17 00 Uhr Seite 78...
Страница 82: ...79 Anleitung_4010363 _ 27 05 2010 17 00 Uhr Seite 79...