background image

34 

 

ITEM NO.  PART NUMBER 

DESCRIPTION 

QUANTITY 

HH06087 

PLATE, TOP AIR (BOTH DOOR TYPE) 

HH06086 

SLIDER, TOP AIR (BOTH DOOR TYPE) 

HH06088 

GASKET, TOP, AIR (BOTH DOOR TYPE) 

HH06108 

DEFLECTOR, TOP AIR (SINGLE DOOR) 

HH06089 

DEFLECTOR, TOP AIR (DOUBLE DOOR) 

HCE05021 

SHAFT, TOP AIR (BOTH DOOR TYPE) 

HHR08045 

SLIDER KNOB, MATT BLACK 

CH08012 

FLUE COLLAR (6") 

CH08032 

FLUE COLLAR GASKET 

CNS07006 

DATA PLATE 

10 

HHR99990/A 

FLUE COLLAR/BLANKING PLATE FIXING PACK 

11 

CH08031 

BLANKING PLATE    

12 

HHR14097 

COVER, TERTIARY AIR INTAKE 

13 

CH08032 

BLANKING PLATE GASKET 

14 

HH06131 

BAFFLE, RECOUPING 

15 

HH06101 

TERTIARY AIR BAR 

16 

HH06115 

BRICK, SIDE, WOOD (EACH) 

17 

HH06116 

BRICK, REAR, WOOD 

1 (BUT SENT IN TWO PIECES) 

18 

HHR99985 

WOOD PLUG (CAM HOLE) 

19 

CNS07014 

WOOD FRONT (SINGLE DOOR) 

19 

CNS0705 

LOG & CATCH BAR (DOUBLE DOOR) 

20 

HFR07040 

OPERATING TOOL 

21 

FRRM06025 

HINGE PIN 

22 

CH08064 

HINGE   

 

CONSORT 9 SLIMLINE 

 MULTIFUEL 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

Содержание DERWENT

Страница 1: ...NT CONSORT 4 CONSORT 5 COMPACT 5 5 SLIMLINE CONSORT 7 9 SLIMLINE CONSORT 9 CONSORT 15 MULTIFUEL AND WOOD CE VII MODELS Instructions for Installation Operating Maintenance Servicing JINCNSDA REV B 06 0...

Страница 2: ...5 COMPACT CONSORT 5 SLIMLINE CONSORT 7 CVSCNC05FM CVSCNC05FW CVCNS05FM CVSCNS05FM CVCN07FM CVSCN07FM CVCNS05FW CVSCNS05FW CVCN07FW CVSCN07FW CONSORT 9 SLIMLINE CONSORT 9 CONSORT 15 CVCNS09FM CVSCNS09F...

Страница 3: ...2 TROUBLESHOOTING 23 24 SPARES 25 36 INSTALLATION COMMISSIONING CHECK LIST 37 SERVICE RECORDS 38 FULL WARRANTY INFORMATION 39 40 Welcome to the Hunter Stoves family and thank you for purchasing a Park...

Страница 4: ...g s 5 0 g s Flue Gas Mass Flow Smokeless Fuel NA 7 9 g s NA NA NA Flue Outlet Size Top or Rear Option 125mm 125mm 125mm 125mm 125mm VENTILATION Where leakage is greater than 5m hour m Ventilation norm...

Страница 5: ...6 4 g s Flue Gas Mass Flow Smokeless Fuel NA NA 8 5 g s 7 2 g s Flue Outlet Size Top or Rear Option 150mm 125mm 150mm 150mm VENTILATION Where leakage is greater than 5m hour m Ventilation normally req...

Страница 6: ...discretion of a qualified installer and a flue draught interference test must be performed Do not obstruct the ventilation required for the safe use of this appliance Competent Persons Scheme Hunter...

Страница 7: ...s appliance should not be operated with the door open If fume emission persists then the following immediate action should be taken Open doors and windows to ventilate the room Let the fire go out or...

Страница 8: ...rward off the rear grate support and lift out of the firebox 3 Remove the cam bar by lifting the left hand end of it upwards until it clears the side casting Pull the left hand end towards the front o...

Страница 9: ...Baffle into the Fire Box and remove Place the bolts downwards through the fixing holes head side upwards Then tighten by using supplied nuts from inside stove Place the gasket on the outlet and put b...

Страница 10: ...10 Re Assembling The Stove Refit all the internal parts by following the removing internal component instructions in reverse order APPLIANCE DIMENSIONS DERWENT CONSORT 4 CONSORT 5...

Страница 11: ...11 COMPACT 5 CONSORT 5 SLIMLINE CONSORT 7...

Страница 12: ...12 CONSORT 9 SLIMLINE CONSORT 9 CONSORT 15...

Страница 13: ...Slimline and 9 Slimline and 152mm Consort 7 Consort 9 Consort 15 It is essential that all connections between the stove and chimney flue are sealed and made airtight Make provision to access the chimn...

Страница 14: ...ice and any other legislation that may have been introduced since the publication of these instructions Competent Persons Scheme Members of the following schemes may self certify the installation of t...

Страница 15: ...fireplace but a permanent free air gap of at least 150mm on top and 50mm at the sides although we recommend 150mm for the sides and 50mm at the back of the stove to obtain maximum heat output and for...

Страница 16: ...e is fitted closed If there any adjoining room s that have an Extractor Fan fitted open the adjoining door to ensure that the chimney flue system is not compromised when the fan is operating If there...

Страница 17: ...tion Act Northern Ireland 2016 In Wales appliances are exempted by regulations made by Welsh Ministers Further information on the requirements of the Clean Air Act can be found here https www gov uk s...

Страница 18: ...r from obstruction and blockage Primary Air This provides a conventional air draught to the bed of the fire Primary air is controlled via the slider s in the door s To increase air move the slider to...

Страница 19: ...id Mineral Fuels To burn solid mineral fuels place the operating tool over the riddling spigot and pull it towards you When left in that position air is directed under and up through the slots in the...

Страница 20: ...embers add some kindling to prevent excessive smoke Maximum Log Length See Technical Specification Ensure your logs are well seasoned with a moisture content of less than 20 Reduced Combustion In orde...

Страница 21: ...lass panel when cool with a propriety glass cleaner Highly abrasive substances should be avoided as these can scratch the glass and make subsequent cleaning more difficult Wet logs on heated glass a b...

Страница 22: ...oves recommend that you contact the installation engineer for advice Remove all the internal components Riddling Bars Cam Bar Catch Bar Ashpan Side Plates and Baffle Clean them carefully with a wire b...

Страница 23: ...e use of dry seasoned wood with less than 20 moisture content Excessive smoke into room when appliance door is opened Low flue draught Speak to your installer Incorrect additional ventilation air in t...

Страница 24: ...oisture content over 20 Use dry seasoned wood less than 20 moisture content Glass blackening Using poor quality wood Use dry seasoned wood less than 20 moisture content Low flue draught Speak to your...

Страница 25: ...PB Spray Paint 400ml 40 011400HSG Flue Damper 5 6 HHR99992 HHR99988 MULTIFUEL FRONT EXTENSION Consort 4 CNS04019 Consort 5 5C CND05015 Consort 7 5S CNS07017 Consort 9S CNS09035 Consort 9 CNS09035 Cons...

Страница 26: ...26 Consort 4 Single Door only Consort 5 and 5 Compact Single Door only Consort 5 Slimline and Consort 7 Double Door LH...

Страница 27: ...27 Double Door RH Single Door Consort 9 Slimline Consort 9 and Consort 15 Double Door LH...

Страница 28: ...05007 HHR08045 Consort 4 HCR06076 HCR06108 HCR06077 HCR06072 HAW04017 HHR08045 Consort 5 5C HH04088 HH04089 HH04078 HH04090 HAW04017 HHR08045 Consort 5 Slimline 7 HH06088 HH06086 MF HH06087 WOOD HH061...

Страница 29: ...29 BODY ASSEMBLY SPARES DERWENT CONSORT 4 MULTIFUEL CONSORT 4 WOOD...

Страница 30: ...30 CONSORT 5 5 COMPACT MULTIFUEL CONSORT 5 5 COMPACT WOOD CONSORT 5 SLIMLINE MULTIFUEL...

Страница 31: ...R99990 A FLUE COLLAR BLANKING PLATE FIXING PACK 1 11 CH05011 BLANKING PLATE 1 12 HHR14097 COVER TERTIARY AIR INTAKE 1 13 CH05042 BLANKING PLATE GASKET 1 14 HHW05063 BAFFLE RECOUPING 1 15 HH06101 TERTI...

Страница 32: ...05042 FLUE COLLAR GASKET 1 9 CNS05018 DATA PLATE 1 10 HHR99990 A FLUE COLLAR BLANKING PLATE FIXING PACK 1 11 CH05011 BLANKING PLATE 1 12 HHR14097 COVER TERTIARY AIR INTAKE 1 13 CH05042 BLANKING PLATE...

Страница 33: ...LAR BLANKING PLATE FIXING PACK 1 11 CH08031 BLANKING PLATE 1 12 HHR14097 COVER TERTIARY AIR INTAKE 1 13 CH08032 BLANKING PLATE GASKET 1 14 HH06131 BAFFLE RECOUPING 1 15 HH06101 TERTIARY AIR BAR 1 16 H...

Страница 34: ...032 FLUE COLLAR GASKET 1 9 CNS07006 DATA PLATE 1 10 HHR99990 A FLUE COLLAR BLANKING PLATE FIXING PACK 1 11 CH08031 BLANKING PLATE 1 12 HHR14097 COVER TERTIARY AIR INTAKE 1 13 CH08032 BLANKING PLATE GA...

Страница 35: ...35 CONSORT 9 SLIMLINE WOOD CONSORT 9 MULTIFUEL CONSORT 9 WOOD...

Страница 36: ...36 CONSORT 15 MULTIFUEL CONSORT 15 WOOD...

Страница 37: ...escription Serial Number COMMISSIONING CHECK Complete Sign YES NO Does the chimney flue system meet the appropriate standard Has the chimney flue system been swept and passed the soundness test Has th...

Страница 38: ...38 SERVICE RECORDS...

Страница 39: ...12 months of the installation date for the second year of the standard warranty to be valid and within every 12 month anniversary thereafter to maintain the validity and coverage of any extended warra...

Страница 40: ...s Group products is not covered under the warranty 6 Consequential loss relating to decorations soft furnishings or other household assets is not covered under the warranty 7 Cost associated with the...

Отзывы: