JINCNS05 RevF 27/04/12
Operating
Instructions
This appliance is
not
suitable for use in a shared
flue
Operation with the door open can cause excess
smoke. This appliance must
not
be operated
with the door open
Aerosol Sprays
Do not use an aerosol spray on or near the
stove when it is alight.
Air Controls
This stove has been designed to burn far more
efficiently than a traditional stove, with the
obvious notable feature of clean glass.
However, for this product to work properly it
must be used correctly. To prevent excess
smoke emissions, the air controls of this
appliance must only be operated as directed in
the instructions.
It is essential that the stove has an adequate air
supply for combustion and ventilation.
Primary Air
Primary air is controlled via the slider in the
door. The amount of air can be increased by
moving the slider to the right. On the double
door versions the amount of air is increased by
moving the sliders outwards.
This provides a conventional air draught to the
bed of the fire.
Secondary Air
Secondary air is controlled via the slider above
the door; it is this “Airwash” that keeps a clean
and uninterrupted view of the fire. The amount
of air can be increased by moving the slider to
the right.
Tertiary Air
Tertiary air aids in good secondary combustion
of the fuel and reducing emissions into the
chimney and environment.
Tertiary air can be controlled by adjusting the
cover plate on the back of the stove.
Warning! -
This Appliance will be hot when in
operation and due care should be taken.
We advise that suitable gloves are used when
operating the Primary and Secondary air
controls, and when opening the door.
Riddling Grate
Your Parkray Stove is fitted with a locomotive
type grate. So that de-ashing can be carried out
cleanly and easily, it is riddled from the outside
of the stove with the doors closed.