Parker SCTSD Скачать руководство пользователя страница 1

Note

The statements made in this operating manual are intended
for users with specialised knowledge.

It is essential that the user checks the statements about the
chosen product for suitability for the functions required.
Because of the various tasks and working processes in any
system, the user must check and make sure that all the
demands regarding the function and safety of the system
are satisfied by the features of the product.

Subject to alteration

ENGLISH

ENGLISH

ENGLISH

Operating manual

Temperature switch

UNIT

11

1

&&&&

Switch status indication

I  = switch output 1

II = Switch output 2

(also error output)

Display of systemtemperature

 in °C or °F;

display of parameters

Arrow key to look back in menu or

to set a higher parameter

Arrow key to look forward in menu

or to set a smaller parameter

value

Enter key to select a parameter

value or to confirm a parameter

value

Display of the unit

LED‘s

4-position

digital display with

variable decimal point

Arrow key up

Arrow key down

Enter / OK

UNIT

Содержание SCTSD

Страница 1: ...atisfied by the features of the product Subject to alteration ENGLISH ENGLISH ENGLISH Operating manual Temperature switch UNIT 11 1 Switch status indication I switch output 1 II Switch output 2 also error output Display of systemtemperature in C or F display of parameters Arrow key to look back in menu or to set a higher parameter Arrow key to look forward in menu or to set a smaller parameter val...

Страница 2: ...M12 5 pol Ub S1 out 0V GND Ub bn ye gn 0V GND 1 3 2 UNIT II I Ub S2 out S1 out 0V GND Ub wh bk bn bl 0V GND 1 2 4 3 UNIT II I Ub S1 out Analog out 0V GND Ub DESINA wh bk bn bl 0V GND 1 2 4 3 UNIT II I Ub Ub S1 out S2 out Analog out 0V GND 0V GND DESINA bn wh bk gr bl 1 2 4 5 3 UNIT II I 4 3 5 2 1 ...

Страница 3: ...e r u t a r e p m e t m e t s y s m u m i n i M A M s k a e p e r u t a r e p m e t e r u t a r e p m e t m e t s y s m u m i x a M 1 P S 1 t n i o p h c t i w S 2 P S 2 t n i o p h c t i w S F F O n o i t a c i d n i f f o A n A 4 t n i o p e e s t u p t u o e u g o l a n a f o g n i t t e S 0 2 0 A m 0 2 0 0 2 4 A m 0 2 4 M o r F t u p t u o e u g o l a n a e h t r o f A m 4 r o 0 e u l a v g n ...

Страница 4: ...necessary for the retention of stored data storage in EEProm To ensure trouble free operation the temperature switch remains internally in the run mode If no key has been pressed for 30 seconds the pressure switch changes back automatically to run mode Activation of the programming mode To exclude the unintentional change of programmed parameters the programming mode can be activated only by the f...

Страница 5: ... points dSP and drS 4 5 Analogue Output The temperature switch has two standardised output signals from 0 20mA or 4 20mA In addition it is possible to calibrate the starting and end values This is a prerequisite for n compatibility with existing systems Examples An output signal from 4 20 mA for 40 C up to 125 C is required Resultant setting values for e g AnA 4 20 Analogue output 4 20 mA see menu...

Страница 6: ...inst higher pressure or aggressive substances mediums Safety sleeve SCA TT 10 XXX Cable SCK 410 03 45 45 Temperature sensor SCTT 10 XXX 07 BSPP Fitting SCA TT 10 1 2 Tube clamp SCSD S27 In addition against higher pressure or aggressive substances mediums Safety sleeve SCA TT 10 XXX TemperatureController SCTSD ...

Отзывы: