background image

Specifications

Port Thread Size

1/2"-20 UNF

Housing

Glass-filled Nylon

Volts DC

12 or 24

Ohm (trigger threshold)

47K

Ambient Fuel Temperature

-40

o

 to +250

o

F (-40

o

 to +121

o

C)

RK30880E

Disconnect the Negative terminal 
from the battery to avoid the 
potential hazard of electrical 
shock. Run the wires in protected 
locations and avoid hot surfaces 
and places that could pinch or 
rub on the wires.

1.  Lubricate o-ring on water 

probe with silicone lube or 
clean motor oil, then install into 
collection bowl. Tighten probe 
body snugly by hand only.

2.  Connect 

BLACK

 wire on 

connector assembly to ground, 

RED

 wire to +12/24 vdc, and 

YELLOW

 wire to either wire of 

supplied lamp (use a supplied 

butt splice connector). This will 
send a ground (-) signal once 
water is detected. 
 

Note: The yellow output wire 
sends a ground signal (-) when 
water is detected. This signal 
can only support a 1 amp load 
so the provided lamp is ideal. 
Should you want this signal to 
trigger a warning device that 
draws more than 1 amp, use 
a relay (customer supplied) 
to drive the device. The 
yellow wire (ground signal) 
should be attached to the coil 
ground terminal of the relay. 
Once water is detected, the 
ground signal will activate the 

coil, thus closing the power 
contacts to drive your device 
(horn, buzzer, etc.).

3.  Use loose black wire (supplied 

with lamp) and butt splice 
connector to connect other 
side of lamp to 1 amp fuse, 
then to +12/24 vdc.

4.  Mount plastic under-dash 

bracket and install lamp into 
bracket hole or drill a 0.50˝ 
(12.7 mm) diameter hole in 
panel and mount lamp directly 
to panel.

5.  Use cable ties to secure any 

loose wires. Reconnect positive 
battery terminal.

Installation Guidelines

Installation Schematic

Red Wire

Black Wire

Yellow Wire

Fuse Box 

(2 amp max.)

Lamp

+

-

+

-

Battery

Ignition 

Switch

Red Wire

Black Wire

Yellow Wire

Fuse Box 

(2 amp max.)

Relay

+

-

+

-

Battery

Ignition 

Switch

Installation Schematic Using 

Customer-Supplied Relay

+

-

Horn, etc.

Содержание Racor RK30880E

Страница 1: ... drain the collection bowl After water has been drained the warning light will reset and no longer be illuminated Instruction Part Number 14400 Rev B Contact Information Parker Hannifin Corporation Racor Division P O Box 3208 3400 Finch Road Modesto CA 95353 phone 800 344 3286 209 521 7860 fax 209 529 3278 racor parker com parker com racor Product Features Includes a warning light and mounting pan...

Страница 2: ...y support a 1 amp load so the provided lamp is ideal Should you want this signal to trigger a warning device that draws more than 1 amp use a relay customer supplied to drive the device The yellow wire ground signal should be attached to the coil ground terminal of the relay Once water is detected the ground signal will activate the coil thus closing the power contacts to drive your device horn bu...

Страница 3: ...20 UNF threads Probe Assembly Warning Light install in panel 0 50 in 12 7 mm diameter hole Yellow wire to one side of warning light This sends a ground signal Black wire to ground Red wire to 12 24 VDC Connector Assembly Black wire from light kit to 1 amp fuse then to 12 24 vdc Water Probe Port 1 2 20 UNF threads ...

Страница 4: ...O PRODUCT OR PART THEREOF THAT IS USED OR BOUGHT FOR USE PRIMARILY FOR PERSONAL FAMILY OR HOUSEHOLD PURPOSES WARRANTIES OF DESCRIPTION WARRANTIES OF MERCHANTABILITY TRADE USAGE OR WARRANTIES OR TRADE USAGE Warning Failure or improper selection or improper use of the products and or systems described herein or related items can cause death personal injury and property damage This document and other...

Отзывы: