background image

All products manufactured or distributed by Racor are subject to the following, and only the following, LIMITED EXPRESS WARRANTIES, and no others: For a period of one (1) year from and after the date of purchase 
of a new Racor product, Racor warrants and guarantees only to the original purchaser-user that such a product shall be free from defects of materials and workmanship in the manufacturing process. The warranty 
period for pumps and motors is specifically limited to ninety (90) days from date of purchase. A product claimed to be defective must be returned to the place of purchase. Racor, at its sole option, shall replace the 
defective product with a comparable new product or repair the defective product. This express warranty shall be inapplicable to any product not properly installed and properly used by the purchaser-user or to any 
product damaged or impaired by external forces. 

THIS IS THE EXTENT OF WARRANTIES AVAILABLE ON THIS PRODUCT. RACOR SHALL HAVE NO LIABILITY WHATSOEVER FOR CONSEQUENTIAL DAMAGES FLOWING FROM THE USE OF ANY DEFECTIVE 
PRODUCT OR BY REASON OF THE FAILURE OF ANY PRODUCT. RACOR SPECIFICALLY DISAVOWS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED INCLUDING, WITHOUT LIMITATION, ALL WARRANTIES OF 
FITNESS FOR A PARTICULAR PURPOSE (EXCEPT FOR THOSE WHICH APPLY TO PRODUCT OR PART THEREOF THAT IS USED OR BOUGHT FOR USE PRIMARILY FOR PERSONAL, FAMILY, OR HOUSEHOLD 
PURPOSES), WARRANTIES OF DESCRIPTION, WARRANTIES OF MERCHANTABILITY, TRADE USAGE OR WARRANTIES OR TRADE USAGE.

Warning! Failure or improper selection or improper use of the products and/or systems described herein or related items can cause death, personal injury and property damage. This document and other information 
from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all 
aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of 
operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making 
the final selection of the products and systems and assuring that all performance, safety and warning requirements of the applications are met. The 
products described herein, including with limitation, product features, specifications, designs, availability and pricing, are subject to change by 
Parker Hannifin Corporation and its subsidiaries at any time without notice.

The following statement is required pursuant to proposition 65, applicable in the State of California: ‘This product may contain a chemical known to 
the State of California to cause cancer or reproductive toxicity’.

GreenMAX 4400 Series

Installation and Service Instructions

3/8 in. (8 mm) 

diameter 

clearance for 

fasteners.

5.91 in.

(15.0 cm)

TOP VIEW

Vent 
Plug

Hand Actuated Primer Pump

OUT

OUT

IN

IN

•  Read all instructions before 

beginning installation. Improper 
installation could cause personal 
injury or property damage.

•  Mounting fasteners and inlet/

outlet port fittings not included.

Specifications:

• Fuel Ports: 7/8”-14 UNF (SAE J1926)
• Max. Flow Rate: 120 GPH (454 LPH)
•     Clean Pressure Drop (@120 GPH): 

0.4 PSI (0.03 bar)

•  Max. Allowable Pressure:

 

30 PSI (2.07 bar)

• Bowl Capacity: 10.1 oz (300 ml)
•  Particulate Removal Efficiency 

(SAE J1985): 90-98%, depending on 

micron rating of filter used

•  Water Removal Efficiency

 

(SAE J1839): min. 95%

•  Ambient Temp. Range:

 

-22

o

 to +212

o

F (-30

o

 to +100

o

C),

 

Max. Fuel Temp: 185

o

F (85

o

C)

•  Suction-side installations

 

recommended

• Do not use on gasoline applications

Water/Contaminant Drain

14.3 in.

(36.3 cm)

6.32 in.

(16.1 cm)

Replacement Parts

1.  RK61713 - Fill Port Plug Kit
2.  N/A - Housing/Head Assembly Kit

 

  (no service kit available)
3.  N/A - Bowl O-ring Kit

 

  (included with replacement filter)
4.  Replacement Filters

 

  (includes bowl O-ring)

 

  R61691S (2 micron),

 

  R61691T (10 micron),

 

  R61691P (30 micron)
5.  RK6166301 - Clear Bowl Kit, no heater

 

  RK6166302 - Clear Bowl Kit, 12vdc heater

 

  RK6166303 - Clear Bowl Kit, 24vdc heater
6.  RK33802 - WIF Sensor Assembly

Instruction Part Number 14461 Rev -

1

2

3

4

5

6

Maintain a clearance of at 
least 4 in. (10.2 cm) below 

filter assembly to service the 

filter and drain the bowl.

Optional Bypass Installation and Operation

(allows user to service filter without shutting down engine)

Valves

1

2

3

Filter On-line

Open

Open

Closed

Filter Off-line

Closed

Closed

Open

Valve 1

Valve 2

If fuel tank is above filter level,

head pressure should not

exceed maximum PSI of filter.

Fuel Tank

(Pressure Side Installation)

Install a shut-off valve 
when fuel tank level is 

higher than filter.

If fuel tank is below filter level, 

lift should not exceed 4 inHg.

Fuel Tank

(Ideal Vacuum 

Side Installation)

Fuel Tank

(Vacuum Side Installation)

Install a check valve, with light or 
no restriction, when tank is lower 

level than filter to maintain prime.

Pressure Side:

Fuel transfer pump not to exceed 

maximum PSI or flow rate of filter.  

Not ideal - pumps emulsify water 

hindering filter performance.

Fuel Transfer Pump

(IDEAL vacuum side 

installation)

Engine

Valve 3

Plug any unused fuel ports.