Parker PSUP Series Скачать руководство пользователя страница 1

 

 

PSUP Mains module

Electromechanical Automation 

We reserve the right to make technical changes. 

192-120147N9 PSUP Manual 2019-06

The data correspond to the current status at the time of printing. 

Installation manual PSUP 

Mains modules 

192-120147N

9

 PSUP Manual

201

9

-

0

6

 

PSU-Manual-Set 

 

Installations-Handbuch PSUP deutsch

 

Installation Manual PSUP english

DOC-00

06

-0

1

DOC-0006-01

Содержание PSUP Series

Страница 1: ...changes 192 120147N9 PSUP Manual 2019 06 The data correspond to the current status at the time of printing Installation manual PSUP Mains modules 192 120147N9 PSUP Manual 2019 06 PSU Manual Set Instal...

Страница 2: ...Tel 49 0781 509 0 Fax 49 0781 509 98176 Internet www parker com eme http www parker com eme E mail sales automation parker com mailto EM Motion parker com Parker Hannifin GmbH registered office Bielef...

Страница 3: ...ent 12 1 9 Supply networks 12 1 10 EC declaration of conformity PSUP 13 2 Device description 14 2 1 Meaning of the status LEDs PSUP mains module 14 2 2 Mounting and dimensions 15 2 2 1 Mounting and di...

Страница 4: ...rage 6 Safety instructions 7 Warranty conditions 9 Conditions of utilization for CE conform operation 10 Conditions of utilization for UL approval PSUP 11 Current on the mains PE leakage current 12 Su...

Страница 5: ...er in the combination Explanation 1 Type designation The complete order designation of the device 2 4 2 PSUPx0 Mains module 3AC 230 480V nominal power in 1kW 10 10kW D6 Designation nominal supply 3 Co...

Страница 6: ...he respectively valid environmental laws The following table states the materials suitable for recycling and the materials which have to be disposed of separately Material suitable for recycling Dispo...

Страница 7: ...1 4 2 Safety conscious working This device may be operated only by qualified personnel Qualified personnel in the sense of these operating instructions consists of Persons who by virtue to their trai...

Страница 8: ...the discharging time must be awaited After switching off the supply voltage it may take up to 10 minutes with additional capacity modules it may take up to 30 minutes to discharge the capacitors Dang...

Страница 9: ...rranty conditions The device must not be opened Do not make any modifications to the device except for those described in the manual Make connections to the inputs outputs and interfaces only in the m...

Страница 10: ...FI03 02 P20 C3 6 x 50 m NFI03 03 P30 C3 6 x 50 m NFI03 03 unshielded Connection length Connection between mains filter and device 0 5 m shielded 5 fully shielded on ground e g ground of control cabine...

Страница 11: ...ctors shall be at least 60 C Use copper lines only Please use the cables described in the accessories chapter they feature a temperature rating of at least 60 C Maximum Surrounding Air Temperature 40...

Страница 12: ...gure of the leakage current depends on the following factors Length and properties of the motor cable Switching frequency Operation with or without external mains filter Motor cable with or without sh...

Страница 13: ...Parker EME EC declaration of conformity PSUP 192 120147N9 PSUP Manual 2019 06 13 1 10 EC declaration of conformity PSUP...

Страница 14: ...ssing off off Error of mains module off on Address assignment CPU active or incorrect wiring flashes quickly Address assignment CPU completed flashes slowly Device state INIT Mains voltage is missing...

Страница 15: ...e that the mounting plate is not exhibited to other temperature influences than that of the devices mounted on this very plate The devices must be mounted vertically on a level surface Make sure that...

Страница 16: ...s module 16 192 120147N9 PSUP Manual 2019 06 2 2 2 Mounting and dimensions PSUP20 PSUP30 Information on PSUP20 PSUP30 4 socket head screws M5 Mounting 100mm 360mm 263mm 96mm 400mm 90 50 5mm 50 5mm 101...

Страница 17: ...age 24VDC PSUP mains module 20 Mains supply PSUP mains module X41 20 Braking resistor temperature switch PSUP mains module 23 2 3 1 Front connector X9 X3 S1 LED1 1 P Mains module PSUP LED1 Status LEDs...

Страница 18: ...available Attention PE connection PE connection with 10mm2 via a grounding screw at the bottom of the device Attention hot surface The heat dissipater can reach very high temperatures 70 C P Mains mo...

Страница 19: ...witch devices off before wiring them Dangerous voltages are still present until 10 min after switching off the power supply Caution When the control voltage is missing there is no indication whether o...

Страница 20: ...voltage 24VDC PSUP mains module Connector X9 Pin Designation Line cross sections minimum 0 5mm2 with conductor sleeve maximum 6mm2 with conductor sleeve AWG 20 10 1 24 V 2 GND24V Control voltage 24 V...

Страница 21: ...A 4xxVAC depending on the input voltage Recommendation ABB S203U K50 440VAC Device protection measure Circuit breakers 80A 700VAC per supply leg in accordance with UL category JFHR2 Requirement Bussma...

Страница 22: ...055 0 45 mH Dimensional drawing LCG 0055 0 45 mH UL Caution Risk of Electric Shock Always switch devices off before wiring them Dangerous voltages are still present until 10 min after switching off th...

Страница 23: ...480 V Minimum braking resistance 27 15 10 Recommended nominal power rating 500 1500 W 500 3500 W 500 5000 W Pulse power rating for 1s 22 kW 40 kW 60 kW Maximum permissible continuous current 13 A 15 A...

Страница 24: ...itoring the braking resistor might be destroyed 2 4 Communication interfaces 2 4 1 Adjusting the basic address On the mains module the basic address of the device combination is set in steps of 16 wit...

Страница 25: ...ircuit breaker K characteristic 25A in accordance with UL category DIVQ Recommendation ABB S203UP K25 480VAC Mains connection PSUP20D6 Device type PSUP20 230V 400V 480V Supply voltage 230VAC 10 50 60H...

Страница 26: ...25A 700VAC per supply leg in accordance with UL category JFHR2 Requirement Bussmann 170M1368 or 170M1568D Control voltage 24 VDC PSUP Device type PSUP Voltage range 21 27VDC Ripple 0 5Vpp Requirement...

Страница 27: ...Protection type IP20 in accordance with EN 60 529 Mechanic resonances Class 2M3 20m s2 8 200Hz Cooling PSUP Cooling mode Forced air ventilation with fan in the heat dissipator EMV limit values PSUP EM...

Страница 28: ...iption 14 E EC declaration of conformity PSUP 13 F Front connector 17 G General hazards 7 I Introduction 4 L LCG 0055 0 45 Mains filter dimensions 22 LEDs 14 M Mains supply PSUP mains module X41 20 Me...

Отзывы: