- 20 -
Display
Function Description
Setup Options and Descriptions
Factory
Setting
Remarks
C-06
Flow rate output voltage
range selection (analog
PV
output range
selection)
0:
0 to 5 Vdc output
1:
1 to 5 Vdc output
0
C-07
Event output 1 type
assignment
0
C-08
Event output 2 type
assignment
0:
Not used (OFF at all times)
1:
ON when alarm activated
2:
Totalization pulse output
3:
On when
PV
is in flow rate OK
judgment range
4:
ON in control mode
5:
ON in fully open mode
6:
ON in control mode or fully open
mode
7:
ON in fully closed mode
8:
Instantaneous
PV
upper limit event
9:
Instantaneous
PV
lower limit event
1
10:
Instantaneous
PV
lower limit event
2
11:
Integrated flow rate event
-1 through -11: Reverse output of 1 to 11
(At no events: ON; at
event occurred: OFF)
0
Flow rate OK judgment range, upper/lower limit
event flow rate, totalized event flow rate and
event output delay time are set in the parameter
setup mode. See “Parameter Setup” for details.
Note the delay time cannot be set to totalization
pulse output.
9:
Events are output even in fully closed
operation mode.
10:
Events are not output in fully closed
operation mode.
-1 through -11: Always OFF during power supply
OFF.
C-10
External switch input 1
function assignment
0
C-11
External switch input 2
function assignment
0:
Not used
1:
Reset totalization
2:
Stop totalization count operation
3:
Switching of
SP
number
4:
Switching of flow rate setup method
5:
Valve fully closed
6:
Valve fully open
7:
Switching of slow start operation
8:
Switching of operating mode:
Contact ON: control mode
Contact OFF: fully closed mode
0
3:
To select three (3) or more
SP
settings,
assign “3” to both ‘
C–10
’ and ‘
C–11
’.
4:
The ‘
C-03
’ (analog/digital) setting is
reversed when the contact is ON.
7:
“Slow start enabled” must be selected in ‘
C-
17
’.
5, 6, 8: When the valve fully closed input and the
valve fully open input are put in at the
same time by two contacts, the both
inputs are disabled.
C-13
Valve automatic shut-off
when the totalization
event occurred
0:
Function disabled
1:
Function enabled
0
When the totalized count value reaches the
totalized event setting value, the valve is fully
closed.
C-14
Resetting the totalized
value at start of control
0:
Function disabled
1:
Function enabled
0
When control is resumed from the fully closed
mode, the totalized value is automatically reset.
C-15
Flow rate alarm setup
type
0:
Not used
1:
Only upper limit alarm used
2:
Only lower limit alarm used
3:
Upper/lower limit alarm used
3
Set the alarm flow rate in the parameter setup
mode. See “Parameter Setup” for details.
FUNCTION SETUP ITEM LIST (continued)