MX80S Series Product Manual
7
Parker Hannifin Corporation
EMN Automation
-
Parker
Irwin, Pennsylvania
Specification Conditions
Specifications Are Temperature Dependent
Catalog specifications are obtained and measured at 20 Degrees C. Specifications at any other
temperature may deviate from catalog specifications. Minimum to maximum continuous operating
temperature range (with NO guarantee of any specification except motion) of a standard unit before
failure is 5
-
40 degrees C.
Specifications Are Mounting Surface Dependent
Catalog specifications are obtained and measured when the positioner is fully supported, bolted
down, and is mounted to a work surface that has a maximum flatness error of:
0.001mm/300mm
(0.00004”/
ft)
Table will operate with work surface of 0.100mm/300mm flatness or worse, but performance speci-
fications will be significantly effected.
Specifications Are Point of Measurement Dependent
Catalog specifications and specifications in this manual are measured from the center of the car-
riage, 38 mm above the carriage surface. All measurements taken at any other location may devi-
ate from these values.
Specifications Are Load Mounting Dependent
Catalog specifications are obtained and measured when the customer load is fixed to the carriage
mounting surface(s) and has a flatness of equal to or less than 0.0025mm
(0.0001”).
The table will
operate with customer load surface greater than 0.0025mm
(0.0001”)
flatness, but performance
specifications will be significantly effected.
Содержание MX80S Series
Страница 10: ...MX80S Series Product Manual 10 Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania 83 6 ...
Страница 34: ...MX80S Series Product Manual 34 Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania Notes ...
Страница 35: ...MX80S Series Product Manual 35 Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania Notes ...
Страница 36: ......