Parker EME
Set-up
192-510014 N04 March 2010
13
Installation of a shaft kit
A
MA
L
K
L
K
P
The sliding carriages of the two linear actuators must stand on the same position
P (Recommendation: push both actuators to the same stop).
Place half-coupling for small shaft diameter on the free shaft ends with distance A
und tighten clamping screw with torque MA. Insert plastic part.
Slide the two other coupling halves on to the connection shaft.
Position connection shaft between the free shaft ends and push the respective
coupling halves towards each other. Caution! Do not push to block – coupling
package must have total length LK.
Tighten clamping screws on both coupling halves on the connection shaft with
torque MA.
Unit
LCB040
LCB060
A
Distance coupling / drive station
mm
8
14
MA
Tightening torque of clamping screws
Nm
1.4
10.5
LK
Length of coupling package
mm
35
66
2.2.3.
Setting the end limits
The software end limits (programmable end limits) can be used to define the
maximum travel path in the positive and negative direction. The machine zero
initiator (home switch) must always be within the software end limits. The switch
must be mounted so that the sliding carriage can under no circumstances travel
beyond (the switch should ideally be mounted in proximity of the drive station or the
deflection station. switching distance 2 – 4 mm) if needs be an additional external
buffer must be fitted.
Caution
The software end limits are not preset. For this reason, they must be defined and entered
into the control system before the unit is placed in service.
Hint
Recommendation: the actual zero point of your controller should be the same as the
machine zero point.