24
IQAN-XS2 Technical Overview
Appendix A
Instruction book, IQAN-XS2
DOUT (on/off output)
Maximum load
2 A
Voltage drop (
VBAT -V
DOUT
)
0.
3
V @ 1.5 A load
Leakage current in off-state
<100 µA, DOUT-A to DOUT-F
<1.0 mA, DOUT-G to DOUT-L
Max load inductance:
200 mH @ 1.5 A load
500 mH @ 1 A load
Short Circuit current limit
6 A
Protection
overload, SCB, SCG
Diagnostics
no
CAN
T
A
= -40 °C to +70 °C (unless otherwise specified)
Parameter
Remark
Number of CAN buses
1
CAN specification
2.0A and 2.0B
CAN bus speed
250 kbits
Protection
SCB, SCG
I/O
T
A
= +25 °C (unless otherwise specified)
Parameter
Remark