IQAN-XC21Instruction book
Publ no HY33-8410-IB/UKEdition 2015-02-18
www.comoso.com
Страница 1: ...IQAN XC21 Instruction book Publ no HY33 8410 IB UK Edition 2015 02 18 www comoso com...
Страница 2: ...C4 pin assignments 11 Supply voltage 12 Emergency stop 12 Connecting of Supply Voltage 12 Polarity reversal 12 Addressing terminating 13 Addressing 13 Terminating 13 Reference voltage VREF 14 Voltage...
Страница 3: ...XC21 8 System Diagnostics 23 Appendix A 24 IQAN XC21 Technical Overview 24 Appendix B 28 Error codes messages and actions 28 LED indicator showing different XC21 modes 28 Appendix C 29 Dimensioning o...
Страница 4: ...n to the term hazardous situation that a person is exposed to a hazard As a way of pointing out important information for the machine designer that in some way relates to safety This includes the desi...
Страница 5: ...ontains product information in a compact format for details on the information found in those documents consult this manual The IQAN module documentation system Compact Documentation Main Documentatio...
Страница 6: ...on the system must be disconnected from other equipment The negative cable must always be disconnected from the battery before disconnecting the positive cable The ground wire of the welder shall be p...
Страница 7: ...only be carried out by trained personnel who are well acquainted with the control system the machine and its safety regulations Before you start Read section Start up Additional information for servi...
Страница 8: ...8 digital inputs DIN A thru DIN H can configured as low side digital outputs DOUT A thru DOUT H The ten 10 inputs DIN J DIN K and DIN A thru DIN H can be configured as frequency inputs FIN A thru FIN...
Страница 9: ...used and well proven within the automotive industry or 2 digital inputs DIN I and DIN L and 10 frequency or pulse count inputs FIN PCNT A thru FIN PCNT J use positions DIN A thru DIN H DIN J and DIN K...
Страница 10: ...n application defined error value for the module inputs and the module outputs will be off The error will be presented on the master display module if there is one and with a related blink code on the...
Страница 11: ...cal impact is avoided e g impact from falling objects or the module being used as a step Locate the module so that air can circulat to eliminate excess heat Ensure that no external heat e g from the e...
Страница 12: ...x AWG 20 22 24 Mating connector Molex no 43025 0800 C2 Pin type loose Molex no 43030 0008 Pin type reel Molex no 43030 0002 Plating Selective gold 0 38 m there is also a 0 76 m version Recommended cab...
Страница 13: ...aisy chain max 5A 7 VBAT Dual pin for VBAT daisy chain max 5A 8 CANH A 9 CANH A 10 ADDR H Pin No Function Alt Function Remark 1 VREF A 2 VIN A DIN M LC6 Xp 3 VREF A 4 VIN C DIN O LC6 Yp 5 VREF A 5V Ma...
Страница 14: ...nction 1 DIN A DOUT A FIN C PCNT C PWMIN A 2 DIN B DOUT B FIN D PCNT D PWMIN B 3 DIN C DOUT C FIN E PCNT E PWMIN C 4 DIN D DOUT D FIN F PCNT F 5 DIN E DOUT E FIN G PCNT G 6 DIN F DOUT F FIN H PCNT H 7...
Страница 15: ...be as close to the battery as possible for safety IQAN expansion modules do not have RTC WARNING Risk of injury To reduce the risk for uncontrolled supply of an IQAN master module i e a short circuit...
Страница 16: ...e terminated internally to be the Bus master and will have no special configuration When an IQAN expansion module is located at the end of the CAN bus then you would use an ID tag having a combined ad...
Страница 17: ...potentiometers VREF positions NOTICE It is strongly recommended to use the module s VREF and VREF to all sensors and potentiometers that are connected to the module inputs This will reduce bad measure...
Страница 18: ...CE The negative terminal of the sensor must not be connected to the chassis Maximum load for VREF position see Appendix A Connecting other 3 wire sensors The same type of connection shown for potentio...
Страница 19: ...nnected to VREF and VIN DIN respectively for 5V signal The current consumption for the input is negligible NOTICE Maximum load for VREF position see Appendix A EXAMPLE Connect the negative terminal of...
Страница 20: ...onnect system voltage BAT to the input through a switch in order to reserve 5Vdc VREF for sensors and potentiometers EXAMPLE Connect the positive and negative terminals of the switch to supply or the...
Страница 21: ...nal to the VREF respectively The sensor signal is connected to the FIN position If the current consumption for the sensor exeeds the maximum load for the VREF the sensor could be connected to the BAT...
Страница 22: ...onal frequency sensor is connected to the VREF and the negative terminal to the VREF respectively The sensor signals are connected to the DFIN and DFIN positions NOTICE The negative terminal of the se...
Страница 23: ...maximum load for the VREF the sensor could be connected to the BAT BAT positions For frequency range and minimum pulse width see Appendix A NOTICE The negative terminal of the sensor must not be conne...
Страница 24: ...oads e g lamps and buzzers Low side digital outputs work by grounding a signal through the module See Appendix A for maximum loads per output EXAMPLE Connect the lamp to the low side digital outputs u...
Страница 25: ...the emergency stop may also shut off the diesel engine or a dump valve and with that depressurize the hydraulic system Prepare for system start WARNING Make sure no one is in dangerous proximity to t...
Страница 26: ...will indicate error status through the red blinking LED This gives an immediate diagnosis as to the nature of the error that has occurred The location of the LED indicators on the IQAN module The LED...
Страница 27: ...erature IEC 60529 2001 IP32 IEC 60068 2 52 1996 Kb 72 h IEC 60068 2 30 2005 Db 55 C 95 RH 6 cycles IEC 60068 2 78 2001 Cab 40 C 93 RH 21 days IEC 60068 2 2 2007 Bb 70 C 72 hours IEC 60068 2 1 1993 Ab...
Страница 28: ...reduce number VIN full scale 5000 mV 100 mV VIN resolution 12 bits 1 22 mV Input impedance 36 kohm in parallel with 10 n Accuracy with external sensor supply with VREF sensor supply 1 10mV 0 5 10mV S...
Страница 29: ...e 6 8 kohm in parallel with 10 nF Maximum continuous voltage 32 V Diagnostics defined in application Number of DPCNT 1 configuration may reduce number Frequency range 0 to 20 000 Hz Minimum pulse widt...
Страница 30: ...duce number Maximum load Single channel DOUT ABCD Combined DOUT EFGH Combined 300 mA 850 mA 850 mA Leakage current in OFF state 200 uA Protection over load SCB SCG Diagnostics Operational ON Operation...
Страница 31: ...east shut down the outputs to increase safety WARNING Don t use the machine if an error message or error code is activated LED indicator showing different XC21 modes Status Flash yellow Normal operati...
Страница 32: ...29 Dimensioning of the IQAN XC21 Appendix C Instruction book IQAN XC21 Appendix C Dimensioning of the IQAN XC21 units mm 18 4 5 2x Recommended screw M4 Max Tt 0 8 Nm 70 67 91 www comoso com...
Страница 33: ...ut notice Parker Hannifin Electronic Controls Division SE 435 35 M lnlycke Sweden Tel 46 31 750 44 00 Fax 46 31 750 44 21 www parker com Parker Hannifin Electronic Controls Division 1651 N Main Street...