IV.
System wiring
4.1 System construction
Flow
Pressure
Fault
signal
Control
signal
UVW Motor cable
Braking
resistor/
Braking
unit
RST power cable
Servo motor
Oil pump
AC220V
FAN
Encoder
signal
Pressure
feedback
Pressure sensor
Control valve
Hydraulic
cylinder
Up level control
Fig 4-1 System construction
Note: during working of the oil pump, the pipe may go empty and hence into a vacuumized state. To keep air
out of pressure sensor, pressure sensor must always be filled with hydraulic oil. Please make sure oil outlet is
installed vertically.
If oil has many impurities
pressure sensor outlet might get blocked and pressure may not be detected. Please
select clear oil.