10
Parker Hannifin Corporation
Helac/Cylinder Division
Enumclaw, Washington USA
www.helac.com
PowerTilt Tilting Coupler
PT-4.5 Service & Repair Manual
HY34-1370
Maintenance
1.
Grease the thrust washers at the two grease
fittings with a high quality Lithium-based
grease. Apply grease until clean grease flows
from the grease reliefs. Severe operating
conditions such as abrasive dust or prolonged
submersion in water may require more
frequent grease applications.
2.
Make sure the grease reliefs are functioning
properly. Open or replace non-functioning
grease reliefs immediately.
NOTICE
Never replace the grease relief
valves with grease fittings or
plugs.
NOTICE
Do not operate the PowerTilt if the
grease reliefs are not functioning.
1.
Check shaft end play. When the end play
exceeds 0.38 mm, the end cap must be
tightened.
2.
Retighten torque foot M10 bolts (114) to 68
Nm (50 ft-lbs) and tie rod bolt nut (411) to 920
Nm (680 ft-lbs)
Daily
Monthly
Maintenance