Parker domnick hunter DNC1050 Скачать руководство пользователя страница 1

domnick hunter Non-Cycling

Refrigerated Dryer

User Guide Rev. D

Models DNC200 - DNC1200

Содержание domnick hunter DNC1050

Страница 1: ...domnick hunter Non Cycling Refrigerated Dryer User Guide Rev D Models DNC200 DNC1200...

Страница 2: ...trols Standard on all models 5 4 Start Up Procedures 6 4 1 When Operating Dryer 6 5 Routine Maintenance 7 6 Maintenance Schedule 8 6 1 Maintenance Procedures 8 7 Troubleshooting Service 9 7 1 Refriger...

Страница 3: ...n ambient temperature between 41 100 F 5 38 C and free from explosive and corrosive fumes Three 3 feet 92cm of space must be allowed between all open grills If the dryer is installed in a confined are...

Страница 4: ...ions To be performed by a qualified person only Risk of serious injury or death Observe Lock out Tag Out Procedure Disconnect lock out and tag all power at source prior to attempting repairs or adjust...

Страница 5: ...D 3 Controls Standard on all models Dryer ON OFF Switch Dryer POWER Light HIGH REFRIGERANT PRESSURE ALARM LOW REFRIGERANT PRESSURE ALARM DEWPOINT TEMPERATURE INDICATOR Adjustable time drain module mou...

Страница 6: ...s may be the result of shipping damage see section 1 0 4 Switch unit on ON OFF indicator will light 5 Do not pass air through the dryer until it stabilizes Typically 5 minutes 6 Once the dryer stabili...

Страница 7: ...bris that might accumulate Remove any debris immediately The strainer should be checked weekly Pre filtration per installation instructions Parker pre filter should be installed directly upstream from...

Страница 8: ...ndensing coil fins air cooled units only Dryer Compressor oil level sight glass 250 to 1200 SCFM Filtration Depressurized dryer Replace pre and after filter elements Dryer Check for refrigerant leaks...

Страница 9: ...for proper voltage Turn dryer on Check fuses and replace if necessary 2 Clean strainer 3 Reduce load 4 Check wiring voltage Replace if necessary 5 Close bypass High Dewpoint 1 Excessive thermal load 2...

Страница 10: ...500 230 3 60 11 4 57 1 1 2 1 5 16 1 25 460 3 60 5 4 23 1 0 6 1 5 7 9 10 575 3 60 5 4 23 1 0 6 1 5 6 3 10 DNC700 230 3 60 15 7 98 1 3 1 2 23 2 35 460 3 60 7 1 38 1 1 5 1 2 11 0 15 575 3 60 7 1 38 1 1 5...

Страница 11: ...r XF0325 NCR XF0500 NCR XF1000 NCR 6 Expansion valve DP34181 404 DP34182 404 1 DP34183 404 DP34185 404 7 Refrigerant filter DP28125 DP28135 8 Hot gas bypass valve DP36062 4 DP36062 2 9A Fan 1 pressure...

Страница 12: ...4 NPT 230V 3PH 60Hz 460V 3PH 60Hz 575V 3PH 60Hz AO050JNFI 050AO AA050JNFI 050AA DNC850 850 3 NPT 1 4 NPT 230V 3PH 60Hz 460V 3PH 60Hz 575V 3PH 60Hz AO050JNFI 050AO AA050JNFI 050AA DNC1050 1050 3 NPT 1...

Страница 13: ...DNC200 DNC1200 USER GUIDE 13 Rev D 11 Associated Drawings REF ADE11374...

Страница 14: ...DNC200 DNC1200 USER GUIDE 14 Rev D REF ADE11374...

Страница 15: ...DNC200 DNC1200 USER GUIDE 15 Rev D REF ADE11374...

Страница 16: ...DNC200 DNC1200 USER GUIDE 16 Rev D REF ADE11374...

Страница 17: ...DNC200 DNC1200 USER GUIDE 17 Rev D REF ADE11374...

Страница 18: ...xploded Views DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 200 EXPLODED ASSY AD11511 2 1 1 16...

Страница 19: ...ev D DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 250 EXPLODED ASSY AD11510 2 1 1 15 2014 26...

Страница 20: ...ev D DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 325 EXPLODED ASSY AD11509 2 1 1 15 2014 26...

Страница 21: ...ev D DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 400 EXPLODED ASSY AD11508 2 1 1 15 2014 26...

Страница 22: ...ev D DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 500 EXPLODED ASSY AD11507 2 1 1 14 2014 26...

Страница 23: ...ev D DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 700 EXPLODED ASSY AD11506 2 1 1 14 2014 12...

Страница 24: ...ev D DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 850 EXPLODED ASSY AD11505 2 1 1 14 2014 12...

Страница 25: ...ev D DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 16 NON CYCLING 1050 EXPLODED ASSY AD11504 2 1 1 14 2014 19...

Страница 26: ...ev D DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 16 NON CYCLING 1200 EXPLODED ASSY AD11503 2 1 1 14 2014 19...

Страница 27: ...dicate a response on a scale of 1 being the lowest to 5 being the highest Condition of Arrival Ease of Installation Ease of Start Up Product Quality Technical Assistance Clarity of Instruction Warrant...

Страница 28: ...nit Padova Italy 39 049 9712 111 www parker com hzd Hiross Zander Essen Business Unit Essen Germany 49 2054 9340 www parker com hzd Engine Filtration Water Purification Racor Dewsbury England 44 0 192...

Отзывы: