Parker D41FE Скачать руководство пользователя страница 1

Bulletin MSG11-5715-688/UK

Proportional Directional 
Control Valve

Operation Manual

Series D*1FE

Pilot Operated

Design

 > 30

Parker Hannifin 
Manufacturing Germany GmbH & Co. KG
Industrial Systems Division Europe
Gutenbergstr. 38
41564 Kaarst, Germany
Tel.: (+49) 181 99 44 43 0
E-mail: [email protected]
Copyright © 2019, Parker Hannifin Corp.

Содержание D41FE

Страница 1: ...e Operation Manual Series D 1FE Pilot Operated Design 30 Parker Hannifin Manufacturing Germany GmbH Co KG Industrial Systems Division Europe Gutenbergstr 38 41564 Kaarst Germany Tel 49 181 99 44 43 0...

Страница 2: ...of the system and components and assuring that all performance endurance maintenance safety and warning requirements of the application are met The user must analyze all aspects of the application fol...

Страница 3: ...g Name Plates 7 Work at the Valve 7 3 Important Details 7 Intended Usage 7 Common Instructions 7 Liability 7 Storage 7 4 Mounting Installation 8 Scope of Supply 8 Mounting 8 Operation Limits 8 Pressur...

Страница 4: ...onic option NG06 pilot Proportional control High repeatability Pilot connections D 1 F C E Design series not required for ordering For details see Catalogue HY11 3500UK For details see Catalogue HY11...

Страница 5: ...e valve The most important features are high dynamic actuator principle with special designed electronic driver closed loop controlled pilot valve and main spool Ensured fail safe behaviour constant c...

Страница 6: ...tion class IP65 in accordance with EN 60529 with correctly mounted plug in connector Supply voltage ripple V 22 30 ripple 5 eff surge free Current consumption max A 3 5 Pre fusing A 4 0 A medium lag I...

Страница 7: ...ded The manufacturer is not liable for warranty claims resulting from this Common Instructions We reserve the right for technical modifications of the described product Illustrations and drawings with...

Страница 8: ...sscross with the following torque values D31FE 13 2 Nm D41FE 13 2 63 Nm D81 91FE 108 Nm D111FE 517 Nm Insufficient condition of the valve mounting surface migth create malfunction Incorrect mountingre...

Страница 9: ...50 m For cable lengths 50 m consult Parker The connection cable is coupled to the female connector by solder joints Skinning lengths for the connecting cable The connection Code 5 requires a 11 PE fem...

Страница 10: ...on observanceofthisinstruc tion may create irreparable damage of valve resp incorporated system parts The backshell nut of the cable gland has to be tighten with a suitable tool The target value for t...

Страница 11: ...eries D 1FE Operation Manual 11 Parker Hannifin Corporation D_1FE 5715 688 UK CM 18 01 2019 Wiring Code 0 6 PE acc EN 175201 804 Code 5 11 PE acc EN 175201 804 Code 7 6 PE acc EN 175201 804 enable 1 D...

Страница 12: ...e valve will reach its powerdownpositionspring actuatedindependently from the command signal value The enable function represents no safety ar rangementagainstunwantedvalveopera tion in terms of rules...

Страница 13: ...nge filtration review valve flushing The overcurrent shutoff condition may be resetted by the actions below Code 0 Temporary disconnection of the supply voltage Code 5 Temporary disconnection of the e...

Страница 14: ...ve parameter The chosen parameters may be optionally stored on the PC via the File menu with the menu item Save as data retrieving is always possible via the function Load file Extended functions The...

Страница 15: ...pprox 0 5 Hz slowly green disable valve OK approx 1 Hz fast green valve error approx 10 Hz very fast green Closer information can be can be displayed via the ProPxD Parametrier software LED Error code...

Страница 16: ...ustment of maximum signal span for negative output signal To match the command signal span to the valve operating range P7 MIN Adjustment of stroke step for valve side A at min operating threshold To...

Страница 17: ...ault report about diagnosis 768 J8 Min supply voltage supervision Adjustment of the minimal supply voltage Below this supply voltage the valve switches off with an error message J9 Relay time out off...

Страница 18: ...will be lost In principle parameters dedicated to a type which deviates from the connected valve may be edited However for data transmitting the correct valve has to be connected If parameters will b...

Страница 19: ...pending on travel direction speed too low drifting without command poor dynamic possible reasons for malfunction corrective actions X hydraulic pump resp motor defective replace hydraulic pump resp mo...

Страница 20: ......

Отзывы: