Parker EME
Compax3 device description
192-120101 N11 C3I11T11 November 2007
49
3.5.5.
Control voltage 24 VDC C3H
Connector
X4 Pin
Description
1 NC
NC
2
Gnd 24 V
GND
3
+24V
24 VDC (power supply)
Control voltage 24VDC Compax3S and Compax3H
Controller type
Compax3
Voltage range
21 - 27VDC
Mains module
with switch-on current limitation, due to
capacitive load
Fuse
MTP miniature circuit breaker or "delayed action
fuse", due to capacitive load
Current drain of the device
0.8A
Total current drain
0.8 A + Total load of the digital o
current for the motor holding brake
Ripple
0.5Vpp
Requirement according to safe extra
low voltage (SELV)
yes
Short-circuit proof
conditional (internally protected with 3.15AT)