Parker EME
Compax3 device description
192-120101 N11 C3I11T11 November 2007
39
3.4.5.
Control voltage 24VDC Compax3MP (mains module)
connector X9
PIN
Designation
1 +24
V
2
Gnd 24 V
Line cross sections:
minimum: 0.5mm
2
with contactor sleeve
maximum: 6mm
2
with contactor sleeve
(AWG: 20 ... 10)
Control voltage 24VDC Compax3MP / Compax3M
Device type
Compax3MP / Compax3M
Voltage range
21 - 27VDC
Mains module
with switch-on current limitation, due to
capacitive load
Fuse
MTP miniature circuit breaker or "delayed action
fuse", due to capacitive load
Current drain of the device
C3MP10D6: 0.2A
Total current drain
C3M050D6: 0.85A
C3M100D6: 0.85A
C3M150D6: 0.85A
+ Total load of the digital o current for
the motor holding brake
Ripple
0.5Vpp
Requirement according to safe extra
low voltage (SELV)
yes
Short-circuit proof
conditional (internally protected with 3.15AT)
3.4.6.
Mains supply Compax3MP (mains module)
By cyclically switching on and off the power voltage, the input current
limitation can be overloaded, which may cause damage to the device.
Wait at least one minute between two switching on processes!
Connector X41
Pin designation
PE
L3
L2
L1
Device protection