![Parker Compax3S025V2 Скачать руководство пользователя страница 202](http://html1.mh-extra.com/html/parker/compax3s025v2/compax3s025v2_operating-instructions-manual_3903775202.webp)
Setting
up Compax3
Positioning via digital I/Os
202
192-120101 N11 C3I11T11 November 2007
Leak effect and windowing
If frequencies not corresponding to the frequency resolution are present in the
analyzed spectrum, the so-called leak effect can be caused.
Display of the leak effect with the aid of a 16 point discrete Fourier transformation
Complete oscillation period in the scanning
period
f
0
Envelope without leak effect
Non complete oscillation period in the scanning
period
f
0
Envelope with leak effect
Sine at 200Hz without windowing
Consequence of the leak effect shown at the example of a sine signal.
(fA=4000Hz; N=500; =>
Δ
f=8Hz
f0=200Hz = 25*
Δ
f frequency corresponds to the frequency-resolution
The sine frequency is exactly on a multiple of the frequency resolution (200Hz /