![Parker Compax3S025V2 Скачать руководство пользователя страница 114](http://html1.mh-extra.com/html/parker/compax3s025v2/compax3s025v2_operating-instructions-manual_3903775114.webp)
Setting
up Compax3
Positioning via digital I/Os
114
192-120101 N11 C3I11T11 November 2007
Setting the time basis XDIV
Setting the time basis XDIV
Depending on the selected operating mode, the time basis can be changed via the
arrow keys.
For the operatiing modes SINGLE, NORMAL and AUTO, the following XDIV
time settings are possible:
XDIV
Mode Scanning time Samples DIV/TOTAL
Measuring time
0.5ms 1 125us
4/40
5ms
1.0ms 2 125µs
8/80
10ms
2.0ms 3 125µs
16/160
20ms
5.0ms 4 125µs
40/400
50ms
10.0ms 5
125µs
80/800
100ms
20.0ms 6
250µs
80/800
200ms
50.0ms 7
625µs
80/800
500ms
100.0ms 8
1.25ms
80/800
1s
200.0ms 9
2.50ms
80/800
2s
500.0ms 10 6.25ms
80/800
5s
1s 11
12.50s 80/800
10s
2s 12
25.00ms
80/800
20s
5s 13
62.50ms
80/800
50s
10s 14
125.00ms
80/800
100s
For the operating ROLL, the following XDIV time settings are possible:
XDIV
Mode Scanning time Samples DIV/TOTAL
2 ms
54
125us
200/2000
2ms 54
125µs
200/2000
4ms 55
125µs
200/2000
10ms 56 125µs
200/2000
20ms 57 125µs
200/2000
40ms 58 125µs
200/2000
100ms 59 250µs
200/2000
200ms 60 625µs
200/2000
Changing the time basis is also permitted during an OSCI measuring sequence.
This means, however, that the current measurement is interrupted and started
again with the changed settings.
Settings for channels 1..4
1: Select channel color