Parker Compax3F Fluid Скачать руководство пользователя страница 3

 

 

Parker EME 

C3 ServoManager 

 

192-121100 N8 September 2014

 

  

The present manual contains the installation instructions for the associated 
Compax3 device series. 

This installation manual does contain only the basic information; for more 

detailed information please refer to the Help-files of the individual Compax3 

device types. 

Compax3 - DVD 

The enclosed self-starting* DVD contains the “C3 ServoManager” software tool for 
configuring, optimizing etc. Compax3. 
Please use always the latest C3 ServoManager version. 
 
Furthermore, the "Parker Integrated Engineering Tool", a software tool for the project 
management of several Parker Motion Control products, can be found on the C3 
DVD. 
Several axes are managed in a common project. The Compax3 ServoManager is 
integrated per "Plug & Play" for each Compax3 axis. The configuration, 
optimization,.. take place in the same way as in an independently working C3 
ServoManager. 
 
 

The "C3 ServoManager" software tool is also functioning independently from 

the Parker Integrated Engineering Tool! 

 
After the installation of the ServoManager you can copy the desired Online help 
system with the "C3 ServoManager Help Installer" (you can select the C3 device 
type as well as the desired language) to your PC. The help system can be called up 
directly from the ServoManager. You will find the complete description of the 
selected device type in these online help files. 
Please note that the help files are associated with defined device and software 
versions. 
 
For reading PDF files you need the "Adobe Acrobat Reader", a software tool which is 
available free of charge. It is distributed and generally accepted throughout the 
world. You can also download it directly from the Adobe website.   
 
 
 
 
 
 
 

 

 

Status of the Manuals: 

Help and PDFs are updated simultaneously. In case of doubt the HTML help shows 
the actual state in comparison to PDF edition. 
For additional HTLM help please refer to our website.   
 
* if your PC has not been set up accordingly, start the "start.htm" file 

 

1.  Notes on the Documents Supplied 

Compax3 - 

Installation Manual 

C3 ServoManager 

Parker Integrated 

Engineering Tool 

Online help system 

Adobe Acrobat 

Reader® 

Содержание Compax3F Fluid

Страница 1: ...he data correspond to the current status at the time of printing Compax3 Fluid Installation Manual Hydraulics Controller Paper version Release as from R09 63 C3Manager Compax3F Unterlagen Software use...

Страница 2: ...656 Offenburg Germany Tel 49 0781 509 0 Fax 49 0781 509 98176 Internet www parker com eme http www parker com eme E mail sales automation parker com mailto EM Motion parker com Parker Hannifin GmbH Si...

Страница 3: ...ndently from the Parker Integrated Engineering Tool After the installation of the ServoManager you can copy the desired Online help system with the C3 ServoManager Help Installer you can select the C3...

Страница 4: ...rator authorization on the target computer Note Several applications running in parallel reduce the performance and operability Especially customer applications exchanging standard system components d...

Страница 5: ...utilization for CE conform operation 10 2 8 EC declaration of conformity Compax3F 11 3 Compax3F device description 12 3 1 State of delivery 12 3 2 Plug and connector assignment Compax3 Fluid 12 3 2 1...

Страница 6: ...id This manual is valid for the following devices C3F001D2 F12 supplement 2 2 Scope of delivery The following items are furnished with the device Manuals Installation manual German English French Comp...

Страница 7: ...ler 001 10V and 0 20mA outputs 16 Bit D2 24VDC device 3 Unique number of the particular device 4 Supply voltage 24 VDC 5 Date of factory test 6 Designation of the feedback system F12 Feedback Module 7...

Страница 8: ...ntains materials that fall under the special disposal regulation from 1996 which corresponds to the EC directory 91 689 EEC for dangerous disposal material We recommend to dispose of the respective ma...

Страница 9: ...e of pertinent norms specifications accident prevention regulations and operational relationships have been authorized by the officer responsible for the safety of the system to perform the required t...

Страница 10: ...d Shielding connection of the valve cables The cable must be fully screened and connected to the Compax3 housing Use the cable clamps shield connecting terminals furnished with the device The shield o...

Страница 11: ...Parker EME EC declaration of conformity Compax3F 192 121100 N8 September 2014 11 2 8 EC declaration of conformity Compax3F...

Страница 12: ...ignment 13 Plug and connector assignment complete 14 Analog Input plug X1 15 Analog Output plug X2 16 Voltage supply plug X3 17 RS232 RS485 interface plug X10 17 Analog Encoder plug X11 18 Digital inp...

Страница 13: ...192 121100 N8 September 2014 13 3 2 2 Plug and connector assignment X1 Analog Inputs X2 Analog Outputs X3 24 VDC power supply X10 RS232 RS485 X11 2 Feedback Type X12 Inputs Outputs X13 1 Feedback Typ...

Страница 14: ...O8 I8 Input24VDC O9 I9 O10 I10 O11 I11 InputGND X22 Input Output option M12 M10 HEDA HEDA motionbus option M11 M10 I Os X20 6 Lx X20 7 res X20 8 res X20 HEDA in X20 1 Rx X20 2 Rx X20 3 Lx X20 4 res X2...

Страница 15: ...IN3 Signal Sensor 3 16 IN3 Signal Sensor 3 17 IN4 10V Input 4 18 IN4 10V Input 4 19 IN5 10V Input 5 20 IN5 10V Input 5 Requirement Connection cable Use shielded cables Shield connection of the cables...

Страница 16: ...Voltage 10V 1000 Current 4 20mA 600 Current 100mA 100 All outputs are short circuit proof Requirement Connection cable Use shielded cables Shield connection of the cables The cable must be fully scree...

Страница 17: ...2 7 RS232 RS485 interface plug X10 Interface selectable by contact functions assignment of X10 1 X10 1 0V RS232 X10 1 5V RS485 PIN X10 RS232 Sub D 1 Enable RS232 0V 2 RxD 3 TxD 4 DTR 5 GND 6 DSR 7 RTS...

Страница 18: ...back system X11 High Density Sub D Pin DA monitor RS422 Encoder Start Stop time of flight SSI 1 24V max 100mA 24V max 100mA 2 3 Aout1 4 Aout0 5 5V for encoder max 150 mA 6 A INIT Clock 7 A INIT Clock...

Страница 19: ...of the device specific assignment in the online help which can be opened from the Compax3 ServoManager Maximum capacitive loading of the outputs 50nF max 4 Compax3 inputs 3 2 9 1 Connection of the di...

Страница 20: ...on the encoder side Vcc 5V controlled on the encoder side Vcc 5V controlled on the encoder side 5 5V for encoder max 150mA 5V 5V 6 A Clock INIT Clock 7 A Clock INIT Clock 8 B COS COS STSP 9 SIN SIN 10...

Страница 21: ...0 N8 September 2014 21 3 2 11 Mounting and dimensions Mounting 3 socket head screws M5 or by direct snapping on a 35 mm supporting rail according to DIN EN 50 022 Mounting material DIN rail clip and d...

Страница 22: ...9 IP 20 Inputs And Outputs Controller type Compax3 F001 D2 8 control inputs 24 VDC 10 kOhm 4 control outputs Active HIGH short circuit proof 24 V 100 mA 4 analog current inputs 14 Bit 2 analog voltage...

Страница 23: ...ion Operation storage transport 85 class 3K3 95 class 2K3 95 class 2K3 Relative humidity Elevation of operating site 1000m above sea level for 100 load ratings 2000m above sea level for 1 100m power r...

Страница 24: ...panel LEDs via X10 12 Mounting and dimensions 21 N Notes on the Documents Supplied 3 P Packaging transport storage 8 Plug and connector assignment 13 Plug and connector assignment Compax3 Fluid 12 Plu...

Отзывы: