Technical Characteristics
Hydraulics Controller
22
192-121100 N8 September 2014
Voltage supply 24VDC
Controller type
Compax3 F001 D2
Voltage range
21 - 27VDC
Mains module
with switch-on current limitation, due to
capacitive load
Fuse
MTP miniature circuit breaker or "delayed action
fuse", due to capacitive load
Current drain of the device
0.8A (max. 1.5A)
Total current drain
0.8A + total load of the digital outputs
Ripple
<1Vss
Requirement according to safe extra
low voltage (SELV)
yes
Size / weight
Controller type
Compax3 F001 D2
Dimensions: HxWxD [mm]
199x80x130
Weight [kg]
2.0
Housing / protection class
Enclosed metal housing, insulation according to
EN60529 / IP 20
Inputs And Outputs
Controller type
Compax3 F001 D2
8 control inputs
24 VDC / 10 kOhm
4 control outputs
Active HIGH / short-circuit proof / 24 V / 100 mA
4 analog current inputs
14 Bit
2 analog voltage inputs
14 Bit
4 analog outputs
16 Bits, current or voltage
2 analog monitor outputs
8 Bit
COM ports
RS232
115200 baud
Word length: 8 bits, 1 start bit, 1 stop bit
Hardware handshake XON, XOFF
RS485 (2 or 4-wire)
9600, 19200, 38400, 57600 or 115200
baud
Word length 7/8 bit, 1 start bit, 1 stop bit
Parity (can be switched off) even/odd
2 or 4-wire
Supported valves and feedback systems
Valves
D1*FH series
Absolute encoder
Analog 0..20mA, 4..20mA, ±10V
Start/Stop - interface
SSI interface
EnDat 2.1-interface
1VSS (max. 400kHz) Interface, 13.5bits /
graduation of the scale
RS422 Encoder (max. 5MHz, (track A or
B) internal resolution quadrature
4. Technical Characteristics