Compax3F device description
Hydraulics Controller
20
192-121100 N8 September 2014
3.2.10.
Feedback (connector X13)
The following position sensors can be connected via X13:
1VSS SineCosine (max. 400Hz)
RS422 Encoder (max. 5MHz, (track A or B) or step/direction)
SSI (RS422)
Start / Stop (Time of Flight, RS422)
EnDat2.1
1. Feedback system / X13 High Density /Sub D
Pin
RS422 Encoder
SineCosine
1VSS
EnDat 2.1
Start/Stop
(time-of-flight)
SSI
1
+24V
max. 100mA
+24V
max. 100mA
2
Sense+
Sense+
Sense+
3
Sin+
Sin+
4
Vcc +5V (controlled
on the encoder side)
Vcc +5V (controlled
on the encoder
side)
Vcc +5V (controlled
on the encoder side)
5
+5V (for encoder)
max. 150mA
+5V
+5V
6
A-
Clock-
INIT-
Clock-
7
A+
Clock+
INIT+
Clock+
8
B+
COS+
COS+
STSP+
9
SIN-
SIN-
10
11
Sense-
Sense-
Sense-
12
B-
COS-
COS-
STSP-
13
N-
N-
DATA-
DATA-
14
N+
N+
DATA+
DATA+
15
GND
GND
GND
GND
GND
Max. start/stop time is 1.6ms (over 4.15m).
+5V (Pin 4) is measured and controlled directly at the end of the line via Sense - and
Sense +.
Note on F12:
Maximum cable length: 100 m
Caution!
Pin 4 and Pin 5 must under no circumstances be connected!
3.2.10.1
Connections of the encoder interface
10nF
+5V
121
Ω
A
1K
Ω
1K
Ω
GND
A B N
RS422
Transceiver
B N
Compax3
The input connection is available in triple (for A & /A, B & /B, N & /N)