![Parker CM2904 Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/parker/cm2904/cm2904_instruction-book_3895864047.webp)
CM2904 Instruction Book © 2009 - 2022 Parker-Hannifin Corporation Page 47 of 51
Summary of Tests
Design Verification Tests
11. Summary of Tests
11.1. Design Verification Tests
The following table lists the design verification tests that were performed for the
product.
Table 23: Design Verification Test Summary
Ref
#
Test Specification
Test Description
Test Level
1
EP455 Section
5.1.1
Operating Temperature
Level 3:
-30…+85 °C
9 cycles,
8h /cycle
2
EP455 Section
5.1.2
Storage Temperature
Level 2:
-40…+85 °C
3
IEC 60068-2-2 Bb
Storage High Temperature
+85 °C, 16 hours
4
IEC 60068-2-1 Ab
Storage Low Temperature
-40 °C, 16 hours
5
ISO 15003 Section
5.2.2
Thermal Shock
Level 3:
-40…+85 °C,
100 cycles
6
ISO 15003 Section
5.2.1
Thermal Cyclic
Level 3:
-40…+85 °C,
7
ISO 15003 Section
5.4
Damp Heat Cyclic Level 2
Level 2:
2 cycles, +55°C
8
ISO 15003 Section
5.10
Chemical Brush Exposure
Urea Nitrogen, Liquid
Lime (Calcium),
Fertilizers, Ammonium
Hydroxide, Diesel fuel,
Petrol, Hydraulic Oil,
Ethylene Glycol
9
*)3
ISO 15003 Section
5.14.1
Operating Voltage
Test voltages: 9 V,
13.6 V, 16 V, 27,2 V,
36V;
One cycle/v 4
cycles in 27,2 V;
10 ISO 15003 Section
5.14.2
Over Voltage
48VDC, 5min
11 AGCO STD 6/2008
Section 2.2.3
Under Voltage
0…8VDC
12
ISO 15003 Section
5.14.3
Reverse Polarity
-26VDC, 5min
13 ISO 15003 Section
5.14.4
Short Circuit Protection
Voltage level = 26V;
Test time = 5min/pin