![Parker AC890PX Series Скачать руководство пользователя страница 370](http://html1.mh-extra.com/html/parker/ac890px-series/ac890px-series_product-manual_755704370.webp)
Programming
D-130
AC890PX AC Drive
REFERENCE STOP
SETUP::SEQ & REF::REFERENCE STOP
This function block holds all the parameters concerning the stopping method of the Drive.
The stopping methods of the Drive are described in more detail in Chapter 8: “Operating the Drive” - Starting and Stopping
Methods.
Parameter Descriptions
RUN STOP MODE
PREF: 102.01
Default: 0
Range: See below
Selects stopping mode that the controller will use once the run command has been removed. The choices are:
Enumerated Value
:
Stopping Mode
0 : RUN RAMP
1 : COAST
2 : DC INJECTION (only Volts/Hz control mode)
3 : STOP RAMP
When RUN RAMP is selected the Drive will decelerate using the reference ramp deceleration time, provided it is non zero.
When COAST is selected the motor will free-wheel. When DC INJECTION is selected the motor is stopped by applying dc
current. When STOP RAMP is selected the motor will decelerate in STOP TIME.
STOP TIME
PREF: 102.02
Default: 10.0 s
Range: 0.0 to 600.0 s
Rate at which the demand is ramped to zero after the ramp has been quenched.
STOP ZERO SPEED
PREF: 102.03
Default: 0.10 %
Range: 0.00 to 100.00 %
Threshold for zero speed detection used by stop sequences.
STOP DELAY
PREF: 102.04
Default: 0.500 s
Range: 0.000 to 30.000 s
Sets the time at which the Drive holds zero speed before quenching after a normal stop or a jog stop. This may be particularly
useful if a mechanical brake requires time to operate at zero speed, or for jogging a machine to position.
Содержание AC890PX Series
Страница 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Страница 25: ...3 4 Installing the Drive AC890PX AC Drive Outline Drawing of AC890PX 132kW 400kW HC471581 page 2 of 2 ...
Страница 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Страница 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Страница 159: ...7 24 The Keypad AC890PX AC Drive Assembly Procedure Mounting Dimensions for the Remote Mounted 6901 Keypad ...
Страница 250: ...Programming D 10 AC890PX AC Drive VALUE INPUT BREAK VALUE INPUT LOSS LEVEL BREAK ENABLE BREAK TYPE UNPROCESSED ...
Страница 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Страница 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...
Страница 391: ...D 151 Programming AC890PX AC Drive Speed Rated Speed No Load Speed synchronous speed Rated Torque Torque ...