D-135
Parameter Reference
AC30V series Variable Speed Drive
PNO
Name
Path(s)
Type
Default
Range
Units WQ
View
Notes MBus
0509 Final Stop Rate
Parameters::Motor Control::Ramp
REAL
1200
1 to 4800
Hz/s ALWAYS
TECHNICIAN
01545
0511 Motor Type
Setup::Motor Control::Control and Type
Parameters::Motor Control::Control Mode
USINT
(enum)
0
0:INDUCTION MOTOR
1:PMAC MOTOR
STOPPED
TECHNICIAN
6
01549
0512 Control Strategy
Same as PNO 511
USINT
(enum)
0
0:VOLTS - HERTZ CONTROL
1:VECTOR CONTROL
STOPPED
TECHNICIAN
6
01551
0515 Speed Loop Pgain
Parameters::Motor Control::Spd Loop Settings
REAL
20.00
0.00 to 3000.00
ALWAYS
TECHNICIAN
01557
0516 Speed Loop I Time
Parameters::Motor Control::Spd Loop Settings
TIME
0.100
0.001 to 1.500
s
ALWAYS
TECHNICIAN
01559
0517 Speed Loop Int Defeat
Parameters::Motor Control::Spd Loop Settings
BOOL
FALSE
ALWAYS
TECHNICIAN
01561
0518 Speed Loop Int Preset
Parameters::Motor Control::Spd Loop Settings
REAL
0
-500 to 500
ALWAYS
TECHNICIAN
01563
0519 Spd Loop Dmd Filt TC
Parameters::Motor Control::Spd Loop Settings
REAL
0.0
0.0 to 15.0
ms
ALWAYS
TECHNICIAN
01565
0520 Spd Loop Fbk Filt TC
Parameters::Motor Control::Spd Loop Settings
REAL
1.0
0.0 to 15.0
ms
ALWAYS
TECHNICIAN
01567
0521 Spd Loop Aux Torq Dmd
Parameters::Motor Control::Spd Loop Settings
REAL
0.00
-300.00 to 300.00
%
ALWAYS
TECHNICIAN
01569
0523 Spd Loop Adapt Thres
Parameters::Motor Control::Spd Loop Settings
REAL
0.00
0.00 to 10.00
%
ALWAYS
TECHNICIAN
01573
0524 Spd Loop Adapt Pgain
Parameters::Motor Control::Spd Loop Settings
REAL
20.00
0.00 to 300.00
ALWAYS
TECHNICIAN
01575
0525 Spd Demand Pos Lim
Parameters::Motor Control::Spd Loop Settings
REAL
110.00
-110.00 to 110.00
%
ALWAYS
TECHNICIAN
01577
0526 Spd Demand Neg Lim
Parameters::Motor Control::Spd Loop Settings
REAL
-110.00
-110.00 to 110.00
%
ALWAYS
TECHNICIAN
01579
0527 Sel Torq Ctrl Only
Parameters::Motor Control::Spd Loop Settings
BOOL
FALSE
ALWAYS
TECHNICIAN
01581
0528 Direct Input Select
Parameters::Motor Control::Spd Direct Input
USINT
(enum)
0
0:NONE
1:ANIN1
2:ANIN2
ALWAYS
TECHNICIAN
01583
0529 Direct Input Ratio
Parameters::Motor Control::Spd Direct Input
REAL
1.0000
-10.0000 to 10.0000
ALWAYS
TECHNICIAN
01585
0530 Direct Input Pos Lim
Parameters::Motor Control::Spd Direct Input
REAL
110.00
-110.00 to 110.00
%
ALWAYS
TECHNICIAN
01587
0531 Direct Input Neg Lim
Parameters::Motor Control::Spd Direct Input
REAL
-110.00
-110.00 to 110.00
%
ALWAYS
TECHNICIAN
01589
0533 Total Spd Demand RPM
Parameters::Motor Control::Spd Loop Diagnostics
REAL
x.xx
-100000.00 to 100000.00
RPM NEVER
TECHNICIAN
01593
0534 Total Spd Demand %
Parameters::Motor Control::Spd Loop Diagnostics
REAL
x.xx
-200.00 to 200.00
%
NEVER
TECHNICIAN
01595
0535 Speed Loop Error
Parameters::Motor Control::Spd Loop Diagnostics
REAL
x.xx
-400.00 to 400.00
%
NEVER
TECHNICIAN
01597
0536 Speed PI Output
Parameters::Motor Control::Spd Loop Diagnostics
REAL
x.xx
-500.00 to 500.00
%
NEVER
TECHNICIAN
01599
0543 Power Stack Fitted
Parameters::Device Manager::Drive info
USINT
(enum)
0:NONE
1:3.5 A 400 V
2:4.5 A 400 V
3:5.5 A 400 V
4:7.5 A 400 V
5:10.0 A 400 V
6:12.0 A 400 V
7:16.0 A 400 V
8:23.0 A 400 V
9:32.0 A 400 V
10:38.0 A 400 V
11:45.0 A 400 V R1
12:60.0 A 400 V R1
13:73.0 A 400 V R1
14:87.0 A 400 V
15:105 A 400 V
16:145 A 400 V
17:180 A 400 V
18:205 A 400 V
19:260 A 400 V
20:45.0 A 400 V
21:60.0 A 400 V
22:73.0 A 400 V
23:315 A 400 V
24:380 A 400 V
25:440 A 400 V
NEVER
ENGINEER
01613
0555 PMAC Max Speed
Setup::Motor Control::Motor Data PMAC
Parameters::Motor Control::PMAC Motor Data
REAL
3000
0 to 100000
RPM ALWAYS
TECHNICIAN
6
01637
0556 PMAC Max Current
Same as PNO 555
REAL
4.50
0.00 to 5000.00
A
ALWAYS
TECHNICIAN
6
01639
0557 PMAC Rated Current
Same as PNO 555
REAL
4.50
0.00 to 5000.00
A
ALWAYS
TECHNICIAN
6
01641
0558 PMAC Rated Torque
Same as PNO 555
REAL
4.50
0.00 to 30000.00
Nm
ALWAYS
TECHNICIAN
6
01643
0559 PMAC Motor Poles
Same as PNO 555
UINT
10
0 to 400
ALWAYS
TECHNICIAN
6
01645
0560 PMAC Back Emf Const KE
Same as PNO 555
REAL
60.0
0.0 to 30000.0
V
ALWAYS
TECHNICIAN
6
01647
0561 PMAC Winding Resistance
Same as PNO 555
REAL
6.580
0.000 to 50.000
Ohms ALWAYS
TECHNICIAN
6
01649
0562 PMAC Winding Inductance
Same as PNO 555
REAL
20.00
0.00 to 1000.00
mH
ALWAYS
TECHNICIAN
6
01651
0563 PMAC Torque Const KT
Same as PNO 555
REAL
1.00
0.00 to 10000.00
Nm/A ALWAYS
TECHNICIAN
6
01653
0564 PMAC Motor Inertia
Same as PNO 555
REAL
0.00100
0.00000 to 100.00000
kgm² ALWAYS
TECHNICIAN
6
01655
0565 PMAC Therm Time Const
Same as PNO 555
TIME
62.000
0.000 to 10000.000
s
ALWAYS
TECHNICIAN
6
01657
Содержание AC30V Series
Страница 140: ...9 24 Setup Wizard AC30V series Variable Speed Drive MONITOR THE DRIVE Figure 9 15 Monitor the Drive and fine tune...
Страница 141: ...Setup Wizard 9 25 AC30V series Variable Speed Drive Figure 9 16 Charting Drive Parameters...
Страница 205: ...Compliance C 10 AC30V series Variable Speed Drive Frame H Frame J Frame K contact Parker for more information...
Страница 341: ...Parameter Reference D 102 AC30V series Variable Speed Drive Setpoint Drive Frequency Frequency 1 Frequency 2...