D-122
Parameter Reference
AC30V series Variable Speed Drive
PNO
Name
Path(s)
Type
Default
Range
Units
WQ
View
Notes MBus
1281
Monitor[10]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03089
1282
Monitor[11]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03091
1283
Monitor[12]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03093
1284
Monitor[13]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03095
1285
Monitor[14]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03097
1286
Monitor[15]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03099
1287
Monitor[16]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03101
1288
Monitor[17]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03103
1289
Monitor[18]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03105
1290
Monitor[19]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03107
1311
Setup
Parameters::Device Manager::Soft Menus
ARRAY[0..19]
ALWAYS
OPERATOR
03149
1312
Setup[0]
Parameters::Device Manager::Soft Menus
UINT
1141
0000 to 2039
ALWAYS
OPERATOR 2
03151
1313
Setup[1]
Parameters::Device Manager::Soft Menus
UINT
1006
0000 to 2039
ALWAYS
OPERATOR 2
03153
1314
Setup[2]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03155
1315
Setup[3]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03157
1316
Setup[4]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03159
1317
Setup[5]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03161
1318
Setup[6]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03163
1319
Setup[7]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03165
1320
Setup[8]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03167
1321
Setup[9]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03169
1322
Setup[10]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03171
1323
Setup[11]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03173
1324
Setup[12]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03175
1325
Setup[13]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03177
1326
Setup[14]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03179
1327
Setup[15]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03181
1328
Setup[16]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03183
1329
Setup[17]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03185
1330
Setup[18]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03187
1331
Setup[19]
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2039
ALWAYS
OPERATOR 2
03189
1900
Selected Application
USINT (enum) 0
0:BASIC SPEED CONTROL
1:AUTO/MANUAL CONTROL
2:SPEED RAISE / LOWER
3:SPEED PRESETS
4:PROCESS PID
5:AUXILLARY COMMS
ALWAYS
TECHNICIAN
04341
1901
RL Ramp Time
Advanced Setup::Application::Raise Lower
TIME
10.0
0.0 to 600.0
s
ALWAYS TECHNICIAN 5
04329
1902
RL Reset Value
Advanced Setup::Application::Raise Lower
REAL
0.0
-500.0 to 500.0
%
ALWAYS
TECHNICIAN 5
04331
1903
RL Maximum Value
Advanced Setup::Application::Raise Lower
REAL
100.0
-500.0 to 500.0
%
ALWAYS
TECHNICIAN 5
04333
1904
RL Minimum Value
Advanced Setup::Application::Raise Lower
REAL
-100.0
-500.0 to 500.0
%
ALWAYS
TECHNICIAN 5
04335
1905
Raise Lower Output
Advanced Monitor::Application::Raise Lower
REAL
0.0
-500.0 to 500.0
NEVER
TECHNICIAN 1,5
04337
1906
Minimum Speed Value
Advanced Setup::Application::Minimum Speed
REAL
-100.0
-100.0 to 100.0
%
ALWAYS
TECHNICIAN 5
04339
1907
Minimum Speed Mode
Advanced Setup::Application::Minimum Speed
USINT (enum) 0
0:PROP WITH MINIMUM
1:LINEAR
ALWAYS
TECHNICIAN 5
04341
1908
Skip Band 1
Advanced Setup::Application::Skip Frequencies
REAL
0.0
0.0 to 1000.0
Hz
ALWAYS
TECHNICIAN 5
04343
1909
Skip Frequency 1
Advanced Setup::Application::Skip Frequencies
REAL
0.0
0.0 to 1000.0
Hz
ALWAYS
TECHNICIAN 5
04345
1910
Skip Band 2
Advanced Setup::Application::Skip Frequencies
REAL
0.0
0.0 to 1000.0
Hz
ALWAYS
TECHNICIAN 5
04347
1911
Skip Frequency 2
Advanced Setup::Application::Skip Frequencies
REAL
0.0
0.0 to 1000.0
Hz
ALWAYS
TECHNICIAN 5
04349
1912
Skip Band 3
Advanced Setup::Application::Skip Frequencies
REAL
0.0
0.0 to 1000.0
Hz
ALWAYS
TECHNICIAN 5
04351
1913
Skip Frequency 3
Advanced Setup::Application::Skip Frequencies
REAL
0.0
0.0 to 1000.0
Hz
ALWAYS
TECHNICIAN 5
04353
1914
Skip Band 4
Advanced Setup::Application::Skip Frequencies
REAL
0.0
0.0 to 1000.0
Hz
ALWAYS
TECHNICIAN 5
04355
1915
Skip Frequency 4
Advanced Setup::Application::Skip Frequencies
REAL
0.0
0.0 to 1000.0
Hz
ALWAYS
TECHNICIAN 5
04357
1916
Preset Speed 0
Advanced Setup::Application::Preset Speeds
REAL
0.0
-100.0 to 100.0
%
ALWAYS
TECHNICIAN 5
04359
1917
Preset Speed 1
Advanced Setup::Application::Preset Speeds
REAL
0.0
-100.0 to 100.0
%
ALWAYS
TECHNICIAN 5
04361
1918
Preset Speed 2
Advanced Setup::Application::Preset Speeds
REAL
0.0
-100.0 to 100.0
%
ALWAYS
TECHNICIAN 5
04363
Содержание AC30V Series
Страница 33: ...4 15 Installation AC30V series Variable Speed Drive Wiring Diagrams APPLICATION 0 BASIC SPEED CONTROL...
Страница 34: ...Installation 4 16 AC30V series Variable Speed Drive Basic Speed Control Wiring...
Страница 35: ...4 17 Installation AC30V series Variable Speed Drive APPLICATION 1 AUTO MANUAL CONTROL...
Страница 36: ...Installation 4 18 AC30V series Variable Speed Drive Auto Manual Control Wiring...
Страница 37: ...4 19 Installation AC30V series Variable Speed Drive APPLICATION 2 RAISE LOWER TRIM...
Страница 38: ...Installation 4 20 AC30V series Variable Speed Drive Raise Lower Trim Wiring...
Страница 39: ...4 21 Installation AC30V series Variable Speed Drive APPLICATION 3 PRESETS SPEEDS...
Страница 40: ...Installation 4 22 AC30V series Variable Speed Drive Presets Speeds Wiring...
Страница 41: ...4 23 Installation AC30V series Variable Speed Drive APPLICATION 4 PID CONTROL...
Страница 42: ...Installation 4 24 AC30V series Variable Speed Drive PID Control Wiring...
Страница 162: ...Sequencing Logic B 2 AC30V series Variable Speed Drive SEQUENCING DIAGRAM...
Страница 174: ...Compliance C 8 AC30V series Variable Speed Drive Conducted Emissions Profile Unfiltered Product Frame D Frame E Frame F...
Страница 277: ...D 80 Parameter Reference AC30V series Variable Speed Drive Setpoint Drive Frequency Frequency 1 Frequency 2...
Страница 325: ...E 2 E Plan Library AC30V series Variable Speed Drive Which then brings up the E Plan page...