Parameter Reference
D-109
AC30V series Variable Speed Drive
PNO
Name
Path(s)
Type
Default
Range
Units
WQ
View
Notes MBus
0352
Inv Time Warning
Parameters::Motor Control::Stack Inv Time
BOOL
NEVER
TECHNICIAN
01231
0353
Inv Time Active
Parameters::Motor Control::Stack Inv Time
BOOL
NEVER
TECHNICIAN
01233
0354
Slip Compensatn Enable
Parameters::Motor Control::Slip Compensation
BOOL
FALSE
ALWAYS
TECHNICIAN 4
01235
0356
SLP Motoring Limit
Parameters::Motor Control::Slip Compensation
REAL
150
0 to 600
RPM ALWAYS
TECHNICIAN 4
01239
0357
SLP Regen Limit
Parameters::Motor Control::Slip Compensation
REAL
150
0 to 600
RPM ALWAYS
TECHNICIAN 4
01241
0360
Slew Rate Enable
Parameters::Motor Control::Slew Rate
BOOL
TRUE
ALWAYS
TECHNICIAN
01247
0361
Slew Rate Accel Limit
Parameters::Motor Control::Slew Rate
REAL
500
1 to 1200
Hz/s
ALWAYS
TECHNICIAN
01249
0362
Slew Rate Decel Limit
Parameters::Motor Control::Slew Rate
REAL
500
1 to 1200
Hz/s
ALWAYS
TECHNICIAN
01251
0364
Stabilisation Enable
Parameters::Motor Control::Stabilisation
BOOL
TRUE
ALWAYS
TECHNICIAN 4
01255
0371
Terminal Voltage Mode
Parameters::Motor Control::Voltage Control
USINT
(enum)
0
0:NONE
1:FIXED
2:AUTOMATIC
ALWAYS
TECHNICIAN 4
01269
0374
Motor Base Volts
Parameters::Motor Control::Voltage Control
REAL
100.00
0.00 to 115.47
%
ALWAYS
TECHNICIAN 4
01275
0380
Power kW
Advanced Monitor::Energy Meter
Parameters::Motor Control::Energy Meter
REAL
x.xx
0.00 to 1000000.00
kW
NEVER
TECHNICIAN
01287
0381
Power HP
Same as PNO 380
REAL
x.xx
0.00 to 1000000.00
HP
NEVER
TECHNICIAN
01289
0382
Reactive Power
Same as PNO 380
REAL
x.xx
0.00 to 1000000.00
kVAr NEVER
TECHNICIAN
01291
0383
Energy kWh
Same as PNO 380
REAL
x.xx
0.00 to 10000000.00
kWh
NEVER
TECHNICIAN 1
01293
0385
Power Factor Est
Same as PNO 380
REAL
x.xx
0.00 to 1.00
NEVER
TECHNICIAN
01297
0386
Power Factor Angle Est
Parameters::Motor Control::Energy Meter
REAL
x.xx
0.00 to 90.00
deg
NEVER
TECHNICIAN
01299
0389
Reset Energy Meter
Parameters::Motor Control::Energy Meter
BOOL
FALSE
ALWAYS
TECHNICIAN 2
01305
0390
Duty Selection
Advanced Setup::Motor Control::Control and Type
Parameters::Motor Control::Feedbacks
USINT
(enum)
1
0:HEAVY DUTY
1:NORMAL DUTY
STOPPED TECHNICIAN
01307
0392
DC Link Voltage
Advanced Monitor::Motor and Drive
Parameters::Motor Control::Feedbacks
REAL
x.
0 to 1000
V
NEVER
TECHNICIAN
01311
0393
Actual Speed RPM
Same as PNO 392
REAL
x.xx
-30000.00 to 30000.00
RPM NEVER
TECHNICIAN
01313
0394
Actual Speed Hz
Same as PNO 392
REAL
x.xx
-1500.00 to 1500.00
Hz
NEVER
TECHNICIAN
01315
0395
Actual Speed Percent
Control Screen
Advanced Monitor::Motor and Drive
Parameters::Motor Control::Feedbacks
REAL
x.xx
-200.00 to 200.00
%
NEVER
OPERATOR
01317
0396
DC Link Volt Filtered
Same as PNO 392
REAL
x.
0 to 1000
V
NEVER
TECHNICIAN
01319
0397
id
Parameters::Motor Control::Feedbacks
REAL
x.x
-500.0 to 500.0
%
NEVER
ENGINEER
01321
0398
iq
Parameters::Motor Control::Feedbacks
REAL
x.x
-500.0 to 500.0
%
NEVER
ENGINEER
01323
0399
Actual Torque
Same as PNO 392
REAL
x.x
-500.0 to 500.0
%
NEVER
TECHNICIAN
01325
0400
Actual Field Current
Same as PNO 392
REAL
x.x
-200.0 to 200.0
%
NEVER
TECHNICIAN
01327
0401
Motor Current Percent
Same as PNO 392
REAL
x.x
0.0 to 500.0
%
NEVER
TECHNICIAN
01329
0402
Motor Current
Same as PNO 392
REAL
x.x
0.0 to 2000.0
A
NEVER
TECHNICIAN
01331
0403
100% Stack Current A
Parameters::Motor Control::Feedbacks
REAL
x.x
0.0 to 500.0
A
NEVER
TECHNICIAN
01333
0404
Stack Current (%)
Parameters::Motor Control::Feedbacks
REAL
x.
0 to 500
%
NEVER
TECHNICIAN 3
01335
0405
Motor Terminal Volts
Same as PNO 392
REAL
x.
0 to 1000
V
NEVER
TECHNICIAN
01337
0406
CM Temperature
Same as PNO 392
REAL
x.x
-25.0 to 200.0
C
NEVER
ENGINEER
01339
0407
Heatsink Temperature
Same as PNO 392
REAL
x.x
-25.0 to 200.0
C
NEVER
ENGINEER
01341
0408
Elec Rotor Speed
Parameters::Motor Control::Feedbacks
REAL
x.x
-1500.0 to 1500.0
Hz
NEVER
OPERATOR
01343
0409
Heatsink OT Trip
Parameters::Motor Control::Feedbacks
REAL
x.x
0.0 to 200.0
C
NEVER
OPERATOR
01345
0410
Heatsink OT Warning
Parameters::Motor Control::Feedbacks
REAL
x.x
0.0 to 200.0
C
NEVER
OPERATOR
01347
0411
Heatsink Hot Warning
Parameters::Motor Control::Feedbacks
REAL
x.x
0.0 to 200.0
C
NEVER
OPERATOR
01349
0412
Stack Frequency
Parameters::Motor Control::Pattern Generator
REAL
4.00
2.00 to 16.00
kHz
ALWAYS
ENGINEER
01351
0413
Random Pattern IM
Parameters::Motor Control::Pattern Generator
BOOL
TRUE
STOPPED ENGINEER
4
01353
0414
Deflux Delay
Parameters::Motor Control::Pattern Generator
TIME
1.000
0.000 to 10.000
s
STOPPED ENGINEER
01355
0415
Positive Torque Lim
Parameters::Motor Control::Torque Limit
REAL
150.0
-300.0 to 300.0
%
ALWAYS
TECHNICIAN
01357
0416
Negative Torque Lim
Parameters::Motor Control::Torque Limit
REAL
-150.0
-300.0 to 300.0
%
ALWAYS
TECHNICIAN
01359
0417
Main Torque Lim
Advanced Setup::Motor Control::Control and Type
Parameters::Motor Control::Torque Limit
REAL
150.0
0.0 to 300.0
%
ALWAYS
TECHNICIAN
01361
0418
Fast Stop Torque Lim
Parameters::Motor Control::Torque Limit
REAL
150.0
0.0 to 300.0
%
ALWAYS
TECHNICIAN
01363
0419
Symmetric Torque Lim
Parameters::Motor Control::Torque Limit
BOOL
FALSE
ALWAYS
TECHNICIAN
01365
Содержание AC30V Series
Страница 33: ...4 15 Installation AC30V series Variable Speed Drive Wiring Diagrams APPLICATION 0 BASIC SPEED CONTROL...
Страница 34: ...Installation 4 16 AC30V series Variable Speed Drive Basic Speed Control Wiring...
Страница 35: ...4 17 Installation AC30V series Variable Speed Drive APPLICATION 1 AUTO MANUAL CONTROL...
Страница 36: ...Installation 4 18 AC30V series Variable Speed Drive Auto Manual Control Wiring...
Страница 37: ...4 19 Installation AC30V series Variable Speed Drive APPLICATION 2 RAISE LOWER TRIM...
Страница 38: ...Installation 4 20 AC30V series Variable Speed Drive Raise Lower Trim Wiring...
Страница 39: ...4 21 Installation AC30V series Variable Speed Drive APPLICATION 3 PRESETS SPEEDS...
Страница 40: ...Installation 4 22 AC30V series Variable Speed Drive Presets Speeds Wiring...
Страница 41: ...4 23 Installation AC30V series Variable Speed Drive APPLICATION 4 PID CONTROL...
Страница 42: ...Installation 4 24 AC30V series Variable Speed Drive PID Control Wiring...
Страница 162: ...Sequencing Logic B 2 AC30V series Variable Speed Drive SEQUENCING DIAGRAM...
Страница 174: ...Compliance C 8 AC30V series Variable Speed Drive Conducted Emissions Profile Unfiltered Product Frame D Frame E Frame F...
Страница 277: ...D 80 Parameter Reference AC30V series Variable Speed Drive Setpoint Drive Frequency Frequency 1 Frequency 2...
Страница 325: ...E 2 E Plan Library AC30V series Variable Speed Drive Which then brings up the E Plan page...