D-104
Parameter Reference
AC30V series Variable Speed Drive
PNO
Name
Path(s)
Type
Default
Range
Units
WQ
View
Notes MBus
0034
Digout Value.Digout 14
Same as PNO 5
BOOL
FALSE
ALWAYS
OPERATOR 2
00595
0037
Digout Value.Relay 11
Same as PNO 5
BOOL
FALSE
ALWAYS
OPERATOR 2
00601
0038
Digout Value.Relay 12
Advanced Monitor::Inputs and Outputs
Parameters::Inputs And Outputs::IO Values
BOOL
FALSE
ALWAYS
OPERATOR 2
00603
0039
Anin 01 Value
Same as PNO 38
REAL
x.x
-100.0 to 100.0
%
NEVER
OPERATOR
00605
0040
Anin 01 Break
Parameters::Inputs And Outputs::IO Values
BOOL
NEVER
OPERATOR 4
00607
0041
Anin 02 Value
Same as PNO 38
REAL
x.x
-100.0 to 100.0
%
NEVER
OPERATOR
00609
0042
Anout 01 Value
Same as PNO 38
REAL
0.00
-100.00 to 100.00
%
ALWAYS
OPERATOR 2
00611
0043
Anout 02 Value
Same as PNO 38
REAL
0.00
0.00 to 100.00
%
ALWAYS
OPERATOR 2
00613
0044
Comms Required
Advanced Setup::Communications::Option
Parameters::Option Comms::Comms
USINT
(enum)
1
1:NONE
4:CANOPEN
7:DEVICENET
9:ETHERNET IP
10:MODBUS RTU
12:PROFIBUS DPV1
13:PROFINET IO
CONFIG
TECHNICIAN
00615
0045
Comms Fitted
Advanced Monitor::Communications::Option
Parameters::Option Comms::Comms
USINT
(enum)
0:UNKNOWN
1:NONE
2:BACNET IP
3:BACNET MSTP
4:CANOPEN
5:CC LINK
6:CONTROLNET
7:DEVICENET
8:ETHERCAT
9:ETHERNET IP
10:MODBUS RTU
11:MODBUS TCP
12:PROFIBUS DPV1
13:PROFINET IO
NEVER
OPERATOR
00617
0046
Comms State
Parameters::Option Comms::Comms
USINT
(enum)
0:SETUP
1:NW INIT
2:WAIT PROCESS
3:IDLE
4:PROCESS ACTIVE
5:ERROR
6:RESERVED
7:EXCEPTION
8:NONE
NEVER
ENGINEER
00619
0047
Comms Supervised
Same as PNO 45
BOOL
NEVER
OPERATOR 4
00621
0048
Comms Trip Enable
Same as PNO 44
BOOL
TRUE
ALWAYS
TECHNICIAN 4
00623
0049
Comms Module Version
Same as PNO 45
DWORD
NEVER
TECHNICIAN
00625
0050
Comms Module Serial
Same as PNO 45
DWORD
NEVER
TECHNICIAN
00627
0051
Comms Diagnostic
Same as PNO 45
USINT
(enum)
0:NONE
1:HARDWARE MISMATCH
2:INVALID CONFIGURATION
3:MAPPING FAILED
4:EXCEPTION
5:UNSUPPORTED OPTION
NEVER
OPERATOR
00629
0052
Comms Diagnostic Code
Same as PNO 45
DWORD
NEVER
OPERATOR
00631
0053
Comms Exception
Same as PNO 45
BYTE
NEVER
TECHNICIAN 4
00633
0054
Comms Net Exception
Same as PNO 45
BYTE
NEVER
TECHNICIAN 4
00635
0055
Read Mapping
Advanced Setup::Communications::Option
Parameters::Option Comms::Read Process
ARRAY[0..15]
CONFIG
TECHNICIAN
00637
0056
Read Mapping[0]
Same as PNO 55
UINT
0627
0000 to 2039
CONFIG
TECHNICIAN 4
00639
0057
Read Mapping[1]
Same as PNO 55
UINT
0681
0000 to 2039
CONFIG
TECHNICIAN 4
00641
0058
Read Mapping[2]
Same as PNO 55
UINT
0000
0000 to 2039
CONFIG
TECHNICIAN 4
00643
Содержание AC30V Series
Страница 33: ...4 15 Installation AC30V series Variable Speed Drive Wiring Diagrams APPLICATION 0 BASIC SPEED CONTROL...
Страница 34: ...Installation 4 16 AC30V series Variable Speed Drive Basic Speed Control Wiring...
Страница 35: ...4 17 Installation AC30V series Variable Speed Drive APPLICATION 1 AUTO MANUAL CONTROL...
Страница 36: ...Installation 4 18 AC30V series Variable Speed Drive Auto Manual Control Wiring...
Страница 37: ...4 19 Installation AC30V series Variable Speed Drive APPLICATION 2 RAISE LOWER TRIM...
Страница 38: ...Installation 4 20 AC30V series Variable Speed Drive Raise Lower Trim Wiring...
Страница 39: ...4 21 Installation AC30V series Variable Speed Drive APPLICATION 3 PRESETS SPEEDS...
Страница 40: ...Installation 4 22 AC30V series Variable Speed Drive Presets Speeds Wiring...
Страница 41: ...4 23 Installation AC30V series Variable Speed Drive APPLICATION 4 PID CONTROL...
Страница 42: ...Installation 4 24 AC30V series Variable Speed Drive PID Control Wiring...
Страница 162: ...Sequencing Logic B 2 AC30V series Variable Speed Drive SEQUENCING DIAGRAM...
Страница 174: ...Compliance C 8 AC30V series Variable Speed Drive Conducted Emissions Profile Unfiltered Product Frame D Frame E Frame F...
Страница 277: ...D 80 Parameter Reference AC30V series Variable Speed Drive Setpoint Drive Frequency Frequency 1 Frequency 2...
Страница 325: ...E 2 E Plan Library AC30V series Variable Speed Drive Which then brings up the E Plan page...