![Parker 890CS Скачать руководство пользователя страница 352](http://html2.mh-extra.com/html/parker/890cs/890cs_product-manual_3748717352.webp)
Programming
Page
D-68
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
PMAC MOTOR 2
SETUP::MOTOR CONTROL::PMAC MOTOR 2
Designed for BRUSHLESS SERVO Motor Control Mode.
The
PMAC Motor block is designed to store parameters needed for the thermal protection of the motor.
Parameter Descriptions
MPS1
PREF: 135.01
Default: 230 V
Range:0 to 600 V
MPS2
PREF: 135.02
Default: 400 V
Range: 0 to 600 V
MPS3
PREF: 135.03
Default: 480 V
Range: 0 to 600 V
These parameters define the waypoints on the motor’s thermal protection curve. They represent AC input voltage (in Volts rms).
CURRENT AT MPS1
PREF: 135.04
Default: 10.60 A
Range:0.00 to 1024.00 A
CURRENT AT MPS2
PREF: 135.05
Default: 10.60 A
Range:0.00 to 1024.00 A
CURRENT AT MPS3
PREF: 135.06
Default: 10.60 A
Range:0.00 to 1024.00 A
These parameters define the rms current at the speed defined below.
SPEED AT MPS1
PREF: 135.07
Default: 2300
Range:0 to 2147483647 rpm
SPEED AT MPS2
PREF: 135.08
Default: 4000
Range: 0 to 2147483647 rpm
SPEED AT MPS3
PREF: 135.09
Default: 4800
Range: 0 to 2147483647 rpm
These parameters define the speed on the waypoint.