Programming
Page
D-18
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
DRIVE CONFIG
SETUP::DRIVE SETUP::DRIVE CONFIG
This block contains general drive set-up parameters.
Parameter Descriptions
DRIVE NAME
PREF: 136.01
Default: 890 DRIVE
Range:
Enter a user name for the drive.
CONTROL MODE
PREF: 136.02
Default: 4
Range: See below
This parameter defines how the drive will control the motor. In firmware v2.x the value is set to PMAC and cannot be changed.
Enumerated Value
:
CONTROL MODE
0 : VOLTS / Hz
1 : SENSORLESS VEC
2 : CLOSED-LOOP VEC
3 : 4-Q REGEN
4 : PMAC
Used to control Permanent-Magnet AC brushless motors.