506 / 507 / 508
DC Controller
HA389427 Issue 14 Technical Manual
aerospace
climate control
electromechanical
filtrationfluid & gas handlinghydraulicspneumaticsprocess controlsealing & shielding
Страница 1: ...506 507 508 DC Controller HA389427 Issue 14 Technical Manual aerospace climate control electromechanical filtration fluid gas handling hydraulics pneumatics process control sealing shielding...
Страница 2: ...d Although every effort has been taken to ensure the accuracy of this document it may be necessary without notice to make amendments or correct omissions Parker Hannifin Manufacturing Limited cannot a...
Страница 3: ...all performance endurance maintenance safety and warning requirements of the application are met The user must analyze all aspects of the application follow applicable industry standards and follow th...
Страница 4: ...lled for your own information Unit used as a refer to Certification for the Inverter Component Relevant Apparatus Unit fitted Wall mounted Enclosure Application Area The equipment described is intende...
Страница 5: ...to discharge to safe voltage levels 50V Use the specified meter capable of measuring up to 1000V dc ac rms to confirm that less than 50V is present between all power terminals and earth 7 Unless other...
Страница 6: ...N61000 3 2 Permission of the supply authority shall be obtained before connection to the low voltage supply CAUTION APPLICATION RISK The specifications processes and circuitry described herein are for...
Страница 7: ...rent Control 4 1 Wire Sizes 4 2 Requirements for UL Compliance 4 3 Motor Overload Protection 4 3 Short Circuit Protection Requirements 4 3 Short Circuit Rating 4 3 Operating Ambient Temperature 4 3 Fi...
Страница 8: ...acturing Limited 5 1 CHAPTER6EMCCERTIFICATIONFOR506 507 508 6 1 Certificates 6 1 CHAPTER7TECHNICALSPECIFICATIONS 7 1 Input Supply 7 1 Speed Control 7 1 Current Torque Control 7 1 Adjustment Range 7 2...
Страница 9: ...otor s shaft to provide the feedback signal A current loop within the speed feedback path ensures that safe current levels are always provided to the armature of the motor up to the level set by the m...
Страница 10: ...ponents provide Isolation for the User These components should be selected to provide a double insulated or reinforced isolation boards for the user suitable for the input supply voltage used The prod...
Страница 11: ...Setpoint Analogue Input 0v to 10V 0 to 100 Speed Input Impedance 66k Ohm 5 10V Reference Analogue Output 10V Reference for Speed and Current Setpoints Load 2mA 6 Current Limit Analogue Input 0 to 10V...
Страница 12: ...ure Output Positive Grd Protective Earth Ground Drive Module Protective Earth Ground Grd Protective Earth Ground Motor Protective Earth Ground Auxiliary Terminals The power must be supplied from an in...
Страница 13: ...o increase time P2 RAMP DOWN Setpoint ramp adjustment clockwise to increase time P3 SPEED STABILITY Speed loop stability clockwise increase response P4 CURRENT CALIBRATION Output current calibration c...
Страница 14: ...her than live and neutral Run connects to Common to Enable Speed Control Current Control Figure 4 2 Wiring Diagram Current Control MAINS FILTER L1 L2 N GRD Fuse 6 5 4 3 2 1 10K I LIMIT 10 V SETPOINT R...
Страница 15: ...se Rating Parker Fuse Isolator Kit Part Numbers 506 3A DC Armature AC Supply Ground 1 5mm2 16AWG 10A LA054664 507 6A AC Supply Ground DC Armature 2 5mm2 14AWG 1 5mm2 16AWG 10A LA054664 508 12A AC Supp...
Страница 16: ...4 Installing the Drive Short Circuit Protection Requirements UL Recognized semiconductor fuses must be installed upstream of the controllers Refer to the semiconductor fuses table on the previous pag...
Страница 17: ...PI FIRING CIRCUIT CURRENT SCALING SW1 CALIBRATED ARMATURE CURRENT SPEED RANGE SCALE ARM VOLTAGE TACHO FILTER TACHO SW3 SW4 ARMATURE VOLTAGE FILTER BLOCK DIAGRAM 506 507 508 100 CURRENT CLAMP SPEED LO...
Страница 18: ...rounding terminals are identified with the International Grounding Symbol IEC Publication 417 Symbol 5019 Fitting Figure 4 3 Product Mechanical Arrangement Allow 50mm above and below product for cooli...
Страница 19: ...5 mm 105 mm 105 mm E 50 mm 50 mm 50 mm F 140 mm 140 mm 140 mm Removing the Cover WARNING Isolate the controller before fitting or removing the cover Remove the cover to access the terminals and switch...
Страница 20: ...ce 4mm 12AWG Cable Terminals Suitable for 2 PE 200mm Flying Leads 2 G F H B E C D A 4 x M5 Inserts for DIN Rail Mounting at chosen height END USER TO AFFIX OWN DIN RAIL HERE TO MOUNT DRIVE 506 507 508...
Страница 21: ...nd Set Up Warning Before applying power check Switch Selection a Mains switch set to intended supply voltage Left 110 120 Right 220 240 b Personality switches SW1 OFF ON 506 0 25 to 3A 0 5 to 3A 507 0...
Страница 22: ...nti clockwise P7 Max Speed Mid b External Speed setpoint to minimum Motor a Check motor is compatible with controller and settings b Check motor and load are free to rotate Wiring a Check there is no...
Страница 23: ...to maximum and check armature voltage does not exceed rated value adjust maximum speed using P7 If a minimum speed setting is required reduce speed setpoint potentiometer to zero adjust minimum speed...
Страница 24: ...replace tacho Motor rotates in the wrong direction Speed is controlled though Motor connections are wrong for required direction with 1 Armature voltage feedback 2 Tacho generator feedback Power off...
Страница 25: ...Set up chapter Stall light comes on after 15 seconds in current control mode Incorrect wiring of run contact Run contact should be wired between the two terminals marked run and 10V Stall light comes...
Страница 26: ...IN MANUFACTURING LIMITED Returning the Unit to Parker Hannifin Manufacturing Limited Please have the following information available The model and serial number see the unit s rating label Details of...
Страница 27: ...C compliance when the unit is used as a component We Parker Hannifin Manufacturing Limited address as below declare under our sole responsibility that the above Electronic Products when installed and...
Страница 28: ...ime Type of controller 15 maximum 20 typical Variable proportional plus integral s Feedback method 1 Va Tacho 0 100 load regulation Max torque speed range 2 2 typically 20 1 0 1 typically 100 1 3 Curr...
Страница 29: ...ental Requirements Operating Temperature 0 to 40o C Derate 1 5 Degree above 40o C Max Operating Temperature 50o C Humidity 85 R H at 40o C non condensing Altitude Above 1000m derate at 1 100m to a max...
Страница 30: ...95 2kV Self Recovery and EN50082 Signal Control Fast Transient Burst BS EN61000 4 4 1995 2kV Self Recovery 2 1995 Power Interfaces Fast Transient Burst BS EN61000 4 4 1995 2kV Self Recovery Emissions...
Страница 31: ...Typical Motor Horsepower Hp 90V Armature 110 120V AC 180V Armature 220 240V AC 1 10 1 6 1 6 1 3 1 6 1 3 1 3 3 4 1 3 3 4 3 4 2 Typical Motor Power kW 90V Armature 110 120V AC 180V Armature 220 240V AC...
Страница 32: ...507 508 HA389427 Product Code Block Product Code Feature 1 Basic Product 506 3 Amp 507 6 Amp 508 12 Amp 2 Livery 00 Standard 01 to 99 Customer 3 Cover 20 IP20 Cover 4 Special Options 00 Standard 01 t...
Страница 33: ...parker com IE Ireland Dublin Tel 353 0 1 466 6370 parker ireland parker com IN India Mumbai Tel 91 22 6513 7081 85 IT Italy Corsico MI Tel 39 02 45 19 21 parker italy parker com JP Japan Tokyo Tel 81...