401/402/403XE Series Product Manual
25
Parker Hannifin Corporation
EMN Automation
-
Parker
Irwin, Pennsylvania
The 401/402/403XE positioner can be mounted in a normal, side, vertical, or inverted orientation. For vertical
(Z axis) mounting, care must be taken since certain ballscrew and load combinations can backdrive in a pow-
er loss situation. For all orientations, the cables should be secured as to not interfere with the movement of
the carriage.
Chapter 4
-
Setup and Usage
Mounting Orientation
Normal
Side
Vertical
Inverted
Mounting Surface Requirements
Proper mounting of the 401/402/403XE positioner is essential to optimize product performance. All specifica-
tions are based on the following conditions:
•
The positioner must be bolted down along its entire length.
•
The positioner must be mounted to a flat, stable surface with flatness error less than or equal to
0.013mm/300mm
(0.0005”/
ft).
•
Catalog specifications may deviate for a positioner mounted to a surface that does not meet the above
conditions.
•
If the surface does not meet the above conditions the surface may be shimmed to comply with these re-
quirements.
•
If mounting conditions require that the table base be overhung, catalog specifications will not be met over
that portion of the table. Additionally, in X
-
Y systems the overhung portion of the Y axis may not meet
specifications due to the additional error caused by deflection of the unsupported base. Contact factory
for guidelines on specifications of overhung applications.
Base Through Hole Mounting
-
401/402/403XE
The 401XE, 402XE and 403XE have counterbored clearance holes in the
base of the unit for mounting. To properly mount the positioner along its en-
tire length, it is required that all counterbored holes be used. See Chapter 2
for hole location and size.
If equipped with a hard cover (R1 option), the cover needs to be removed to
access the holes. To do so, use a 2.0mm hex wrench to remove the two but-
ton head screws at each end of the cover.