11
4.4.2.2 PZD3—PZD10
The mapping relation between PZD3—PZD10 and drive parameters is set by master
according to GSD configuration information. When master configures slave parameters, master
will send mapping address between PZD3-PZD10 and drive parameters. If adapter module
receives 0x0000 parameter address, it means user does not set parameter address, this PZD will be
skipped.
Address range
Default address
PZD3(master->slave)
0--0xFFFF
0x0000
PZD4(master->slave)
0--0xFFFF
0x0000
PZD5(master->slave)
0--0xFFFF
0x0000
PZD6(master->slave)
0--0xFFFF
0x0000
PZD7(master->slave)
0--0xFFFF
0x0000
PZD8(master->slave)
0--0xFFFF
0x0000
PZD9(master->slave)
0--0xFFFF
0x0000
PZD10(master->slave)
0--0xFFFF
0x0000
PZD3(slave->master)
0--0xFFFF
0x0000
PZD4(slave->master)
0--0xFFFF
0x0000
PZD5(slave->master)
0--0xFFFF
0x0000
PZD6(slave->master)
0--0xFFFF
0x0000
PZD7(slave->master)
0--0xFFFF
0x0000
PZD8(slave->master)
0--0xFFFF
0x0000
PZD9(slave->master)
0--0xFFFF
0x0000
PZD10(slave->master)
0--0xFFFF
0x0000
V.
GSD file
GSD file is ASCII-format device description file in a specified form. Each device
(master/slave stations) on PROFIBUS has to have its own GSD file.
GSD file of 10P-0008 is
AC10PROF.gsd.
VI.
Application
This chapter gives information on configuring the PROFIBUS master station (Simens PLC S7-
300) and AC10P inverter for communication through 10P-0008 PROFIBUS DP adapter module.