Parker’s portable magnetizing
coils are designed for
magnetic particle inspection of
ferrous metal parts. The coils
allow for the use of either dry
powder or wet fluorescent
inspection media and may be
used for demagnetizing
as well.
The coils are molded in a
tough, black polyurethane and
come equipped with a 10’
(3.048 m) power cord including
a foot switch or optional hand
switch. The sealed electrical
connection box has a 2”
(50.8 mm) X 5” (127.00 mm)
flat base allowing the coil to
stand in a vertical position.
The PL-8, PL-10, PL-8PDC, and PL-10PDC operate from a standard 115VAC, 60
Hz single phase grounded power source.
The PL-8S and PL-10S operate from 230VAC 50-60 Hz single phase grounded
power source. The PL-8S and PL-10S are sold without power cord plugs. Only
locally approved plugs should be used and installed by certified personnel.
Using an approved GFCI is recommended.
PARKER
RESEARCH
CORP
BULLETIN 277
MARCH 2014
PORTABLE MAGNETIZING COILS
PARKER RESEARCH CORP.
PL-8
PL-10
www.calcert.com
1.800.544.2843
0
5
10
15
20
25
30