Pneumatic Division North America

Richland, Michigan 49083

Installation and Service Instructions
3R100P

1/4" PR364 & 1/2" PR10 Regulators

ISSUED:  

April, 2003

Supersedes:  

January, 2003

Doc.# 3R100, ECN# 030337, Rev. 3

!

 

WARNING

To avoid unpredictable system behavior that can cause personal injury
and property damage:

• Disconnect electrical supply (when necessary) before installation,

servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected to

this product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,

and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is below

freezing.

• Service according to procedures listed in these instructions.

• Installation, service, and conversion of these products must be

performed by knowledgeable personnel who understand how
pneumatic products are to be applied.

• After installation, servicing, or conversion, air and electrical

supplies (when necessary) should be connected and the product
tested for proper function and leakage. If audible leakage is present,
or the product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be covered

by paint, etc. If masking is not possible, contact your local
representative for replacement labels.

!

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF
THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR
RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND
PROPERTY DAMAGE.

This document and other information from Parker Hannifin Corporation,
its subsidiaries and authorized distributors provide product and/or
system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application,
including consequences of any failure and review the information
concerning the product or systems in the current product catalog. Due
to the variety of operating conditions and applications for these products
or systems, the user, through its own analysis and testing, is solely
responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements
of the application are met.
The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject
to change by Parker Hannifin Corporation and its subsidiaries at any
time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

Introduction

Follow these instructions when installing, operating, or servicing
the product.

Application Limits

These products are intended for use in general purpose
compressed air systems only.

Operating Pressure:

kPa

PSIG

bar

Maximum Inlet Pressure

2068

300

21.0

Operating Temperature Range:

4°C to 66°C (40°F to 150°F)

ANSI Symbols

Installation

1. The regulator should be installed with reasonable

accessibility for service whenever possible - repair service
kits are available. Keep pipe and tubing lengths to a
minimum with inside clean and free of dirt and chips. Pipe
joint compound should be used sparingly and applied only

to the male pipe - never into the female port. Do not use
PTFE tape to seal pipe joints - pieces have a tendency to
break off and lodge inside unit, possibly causing
malfunction.

2. Install regulator so that air flow is in the direction of arrow.

Installation must be upstream (high pressure) side and as
close to the devices it is to service (valve, cylinder, tool,
etc.) as possible. Mounting may be in any position.

3. Gauge ports are located on both sides of the regulator

body for your convenience. It is necessary to install a
gauge or pipe plugs into each port during installation.

4. For protection against rust, pipe scale, and other foreign

matter, install a filter on the upstream (high pressure) side
as close to the regulator as possible.

Operation

1.

Before turning on the air supply:

1A. On PR364, disengage the adjusting knob by pulling upward.

Turn adjusting knob counterclockwise until the compression
is released from the pressure control spring.

1B. On PR10, push down on the adjusting knob while turning

knob counterclockwise until the compression is released
from the pressure control spring. (Knob is locked when
up.)

2. Then turn on air supply and adjust regulator to desired

secondary pressure by turning adjusting knob clockwise.
This permits pressure to build up slowly, preventing any
unexpected operation of the valve, cylinders, tools, etc.,
attached to the line. Adjustment to desired secondary
pressure can be made only with primary pressure applied
to the regulator.

3.

To decrease regulator pressure setting, always reset from
a pressure lower than the final setting desired. For example,
lowering the secondary pressure from 550 to 410 kPa (80
to 60 psig) is best accomplished by dropping the secondary
pressure to 350 kPa (50 psig), then adjusting upward to
410 kPa (60 psig).

 

!

 

WARNING

Product rupture can cause serious injury.

Do not connect regulator to bottled gas.

Do not exceed maximum primary pressure rating.

Relieving Regulator

Adjustable

Non-Relieving Regulator

Adjustable