background image

Installation & Operating Instructions

!

CAUTION: Solenoid versions of this valve contain solid
state components that can be damaged by transient
voltage spikes, over-voltage or high temperature. To
protect against premature solenoid failure, please read
and adhere to the following:

1. If this solenoid operated valve is used in a circuit with other

inductive loads, the solenoid should be electrically protected
with a voltage suppression device (e.g. transient voltage
suppressor or varistor) that has a minimum rating of 1.6
times the rated voltage of the solenoid valve and sufficient
capacity to dissipate the energy of other inductive loads.

2. Operating voltage is 85-110% of rated voltage. These limits

should not be exceeded.

Valve should be installed with reasonable accessibility for service
whenever possible - repair service kits are available. Keep pipe
or tubing lengths to a minimum with inside clean and free of dirt
and chips. Pipe joint compound should be used sparingly and
applied only to the male pipe -  never to the female port. Do not
use PTFE tape to seal pipe joints - pieces have a tendency to
break off and lodge inside the unit, possibly causing malfunction.

Valves will operate when mounted in any position.

Lubrication

All valves are pre-lubricated at assembly with a petroleum based
grease. Filtered and lubricated air is necessary for maximum
valve life and minimum maintenance. If in-service lubrication is
used, lubricants should be a straight paraffin based mineral oil
having an ISO viscosity grade of 32 (e.g. Sunvis 932).

NOTE: Once in-service lubrication is initiated, the practice should

be continued in order to maximize valve life.

!

CAUTION: Do not use synthetic, reconstituted, or oils
with an alcohol content or detergent additives.

Introduction

Follow these instructions when installing, operating, or servicing
the product.

Application Limits

These products are intended for use in general purpose
compressed air systems only.

Operating Pressure Range:

kPa

psig

bar

Minimum

280

40

2.8

Maximum

1030

150

10.3

Ambient Temperature  Range:

-15°C to 50°C (5°F to 120°F)

Voltage Range:

Rated V10%, -15%

!

CAUTION: An interruption of 10 milliseconds or greater
to the power supplied to the solenoid of a solenoid
operated valve may cause the valve to shift. Provision
must be made to prevent power interruption of this
duration to avoid unintended, potentially hazardous,
consequences.

!

 

WARNING

This valve/base (with wiring in the base) has a standard ISO
5599-2: 1990 mounting interface. Valve bodies labeled Parker
Model 45_, and bases marked ISO 2E, 3E, or 4E or simply O 2E,
O 3E, or O 4E (opposite the junction box under the valve body)
- and without blue wires in the base - can be connected to this
valve/base, but may have incompatible wiring. Base wiring may
be reversed, resulting in unpredictable machine function that
may cause injury, property damage, or death. Completely test
the machine for correct function before using, and rewire if
necessary. Call 1-800-272-7537 for special ISO Valve Service
Bulletin No. VAL-SIF73.

Pneumatic Division North America
Richland, Michigan 49083

!

!

 

WARNING

To avoid unpredictable system behavior that can cause personal
injury and property damage:

• Disconnect electrical supply (when necessary) before installation,

servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected to

this product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,

and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is below

freezing.

• Service according to procedures listed in these instructions.

• Installation, service, and conversion of these products must be

performed by knowledgeable personnel who understand how
pneumatic products are to be applied.

• After installation, servicing, or conversion, air and electrical

supplies (when necessary) should be connected and the product
tested for proper function and leakage. If audible leakage is present,
or the product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be covered

by paint, etc. If masking is not possible, contact your local
representative for replacement labels.

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF
THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR
RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND
PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation,
its subsidiaries and authorized distributors provide product and/or
system options for further investigation by users having technical
expertise. It is important that you analyze all aspects of your application,
including consequences of any failure and review the information
concerning the product or systems in the current product catalog. Due
to the variety of operating conditions and applications for these products
or systems, the user, through its own analysis and testing, is solely
responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements
of the application are met.
The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject
to change by Parker Hannifin Corporation and its subsidiaries at any
time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

Installation & Service Instructions
V-408CP

H4 Series Valves
2-Position, 4-Way, 5-Ports &
3-Position, 4-Way, 5-Ports
Meets ISO 5599-2 / 5599-1

ISSUED:  September, 2000
Supersedes:  October, 1999

ECN# P27805

www.comoso.com

Содержание H4 Series

Страница 1: ... may be reversed resulting in unpredictable machine function that may cause injury property damage or death Completely test the machine for correct function before using and rewire if necessary Call 1 800 272 7537 for special ISO Valve Service Bulletin No VAL SIF73 Pneumatic Division North America Richland Michigan 49083 WARNING To avoid unpredictable system behavior that can cause personal injury...

Страница 2: ...Cylinder Ports Open to Pressure Double Solenoid 3 Position 4 Way Cylinder Ports Open to Pressure Condition with spool in center position 14 End 12 End 4 2 5 3 1 14 End 12 End 4 2 5 3 1 14 End 12 End 4 2 5 3 1 4 2 5 3 1 4 2 5 3 1 Maintenance Troubleshooting Hints Valve Not Shifting Completely When Energized 1 Check to insure that the proper voltage is supplied to the solenoids 2 Check to insure tha...

Страница 3: ...ndicator Unlighted Light B9 Blue 24 K252 030 K252 029 42 24 K252 031 43 24 K252 032 45 12 K252 032 49 24 K252 033 K252 034 51 48 K252 035 53 120 110 K252 036 K252 037 57 240 K252 038 59 240 K252 039 83 120 110 K252 040 K252 041 Low watt with surge suppression This coil contains an MOV as standard for surge suppression Servicing Plunger Assembly 1 Remove the nut item 19 which secures the solenoid c...

Страница 4: ...piston 15 End Bumper Seal for solenoid or air operator 16 Manual Override Stem 17 Override Retainer Item Description 18 Solenoid Coil includes gasket 19 Hex Nut Solenoid 20 Solenoid Plunger Guide Assembly 21 O ring plunger guide assembly to adapter block 22 Override Spring 23 Adapter Block 24 Gasket solenoid base or air operator to adapter has a tab without any letter on it 25 Operator Adapter 26 ...

Страница 5: ...END SOLENOID COIL 12 END 2 3 SOLENOID COIL 4 PIN MICRO TOP COVER WHT BRN BLUE BLK 14 END SOLENOID COIL 12 END 5 PIN MINI TOP COVER 1 2 3 4 SOLENOID COIL 4 PIN MICRO TOP COVER WHT BRN BLUE BLK 14 END 1 2 3 4 5 SOLENOID COIL 5 PIN MINI TOP COVER RED WHT GREEN BLK Chrysler Connection Straight or 90 Receptacle 5 Pin Male Single Solenoid Encl Options 3 5 Auto Option C 4 Pin Male Single Solenoid Encl Op...

Страница 6: ...6 H4 Series Valves V 408CP www comoso com ...