Device Maintenance & Cleaning
Страница 1: ...Parata 2015 All Rights Reserved Revised Date July 2018 ATP 71 Device Maintenance Cleaning...
Страница 2: ...use of the information herein will not infringe any rights or any implied warranties of merchantability or fitness for a purpose Parata reserves the right to make changes to the content of this manua...
Страница 3: ...utdown Procedure 11 Status Display and Front Panel 11 Cabinet Lock 12 Anatomy of Tablet Canister 13 Installing Canisters 14 Refilling Canisters 14 Using the UTC Tray 15 Installing Packaging Paper 16 R...
Страница 4: ...ATP 71 Device Maintenance Cleaning TD79 4 Before Calling for Service 28 Cabinet 28 Canisters 28 Parata Computer 28...
Страница 5: ...ATP 71 device must be operated in a temperature range of 59 82 F 15 28 C with a relative humidity between 20 70 Warning Using this equipment in any manner not specified by the manufacturer may result...
Страница 6: ...upplying voltage that does not exceed 115 VAC 10 60 Hz 9 0 amperes with transient overvoltage in accordance with UL Installation Categories Overvoltage Categories II Consistent with pollution degree 2...
Страница 7: ...vel stable and even Avoid damp locations Avoid extremely dry locations Do not install the ATP 71 near water pipes or sinks Do not install the ATP 71 near heaters stoves or other sources of heat Avoid...
Страница 8: ...al outlet that is easily accessible from the intended operating location Warning Do Not use a three prong to two prong adapter Do not use an extension cord if the intended outlet is too far from the i...
Страница 9: ...increased risk of fire In the event of operational problems disconnect the ATP 71 from its power source until it can be serviced by qualified personnel Always disconnect the ATP 71 from its power sour...
Страница 10: ...cabinet Do not stand or sit on the top of the ATP 71 cabinet Do not lean on the ATP 71 cabinet when any of the drawers are open Take care when cleaning the interior of the ATP 71 not to inhale pill du...
Страница 11: ...the power cord from the electrical outlet wall socket to disable power Warning To completely disconnect all electrical power from the unit disconnect the power cord from the wall socket Status Displa...
Страница 12: ...ng dispensing Up to four medications can be displayed at one time To see the fifth or greater medication press this button to view the next screen Press again to return to the original screen Also use...
Страница 13: ...n on canister access door when open as this may cause the ATP 71 to tip forward Do not open more than one access door at once as this may cause the ATP 71 to tip forward Anatomy of Tablet Canister ATP...
Страница 14: ...tion for each canister Drawer canister positions are marked on the front of each drawer in the ATP 71 cabinet and on the top of the canisters 2 Place the canister into the target position taking care...
Страница 15: ...the canister back in its assigned location 8 Push the canister drawer securely back into the ATP 71 cabinet 9 Close cabinet door 10 Push start button on the ATP 71 front panel to resume operation Usin...
Страница 16: ...the ATP 71 s heating elements as they are hot enough to cause burns Use only packaging paper approved for use by Parata Failure to use approved paper may result in damage to the ATP 71 device 1 Open t...
Страница 17: ...ches 20 centimeters of packaging paper between the rollers as shown in Figure 2 10 Figure 2 10 Paper through the rollers 8 Close the rollers 9 Lower the small hopper mechanism When closing spread open...
Страница 18: ...mselves to the drawer contents as shown in Figure 2 12 Figure 2 12 Packaging assembly drawer 3 Pull the white release handle on the left hand side of the ink ribbon compartment to the left to unlock t...
Страница 19: ...lem an error message will display on the ATP 71 status display Please refer to Table 3 2 or the ATP 71 system software manual for instructions on troubleshooting CHAPTER 3 CLEANING This chapter introd...
Страница 20: ...t one time or lean on the drawers as this increases the risk of the ATP 71 cabinet tipping forward 4 Remove the canister from the drawer and clean the drawer with a lint free dry cloth or HEPA vacuum...
Страница 21: ...ion 7 Close the drawer and cabinet door 8 Press start button on the front panel Note The separator on the base of the tablet canister may require periodic replacement by TCGRx s service staff If crack...
Страница 22: ...gure 3 4 cleaning the hoppers 3 If necessary use alcohol to clean the large hopper Caution Do not use alcohol on the white slip sheet as this may cause the sheet to distort Do not use any substances o...
Страница 23: ...uum cleaner to clean away dust and dirt from within the drawer and around the paper mechanism as shown in Figure 3 6 Figure 3 6 Cleaning around the packaging assembly Caution Do not touch the heater o...
Страница 24: ...vent dirt buildup 7 Pull the pinch roller open and clean them using a dry lint free cloth Figure 3 7 Heat sealer assembly and pinch rollers looking from the left side of the drawer Cleaning the UTC Tr...
Страница 25: ...Monthly or more frequently Grease solenoid Once a year Clean TC sensor Monthly or more frequently as needed Replace cassette brush Every 1 500 000 dispenses Replace TC shelf Every 3 000 000 dispenses...
Страница 26: ...el Ribbon Alarm The ribbon has run out Replace the ribbon Press the Start button on the front panel Drawer Open One or more of the three cabinet drawers is not closed completely Make sure that all the...
Страница 27: ...If obstructions are found remove them and close the drawer Press the Start button on the front panel If the alarm continues contact service for assistance Conveyor Alarm The conveyor is not operating...
Страница 28: ...3 Try moving a canister to a different position and observe how the machine responds 4 Check the output photosensor and clean if necessary Parata Computer 1 Determine whether the PC and monitor are p...