1. Plumb the Flow Switch in the main
header after the filter. (Fig.10)
2. A licensed electrician should make all
electrical connections. Make sure the
unit is grounded by connecting to the
pool equipment bond wire to comply
with local electrical codes.
3. Turn off power to the filtration system
pump at the circuit breaker. (Fig 11)
4. Install an approved seal tight flex
conduit (not included) rated for
outdoor use between the breaker
panel and the flow switch and between
the ClearO3 and the breaker panel.
(Fig. 10)
5. Connect the black leg of the ClearO3
to normally open terminal of the flow
switch. (Fig. 12)
6. Connect a black wire to one of the
terminals of the filter pump breaker
and the other end to the power in
(common) terminal of the flow switch.
(Fig. 12)
7. Connect the red leg of the ClearO3
to the other terminal of the filter pump
breaker if a 220V circuit (Fig. 13)or to
the common bar in the electrical panel
for a 120V circuit. (Fig. 14)
8. Connect the green ground wire from
the ClearO3 to the ground bar in the
breaker panel. (Fig. 14)
Fig. 11
THE CLEARO3 UNIT IS FACTORY SET TO 240VAC. THE CLEARO3
SHOULD BE WIRED TO RUN WITH THE FILTER PUMP WHICH CREATES
THE AIR DRAW THROUGH THE UNIT NEEDED TO CREATE OzONE. DO
NOT SET THE CLEARO3 TO RUN WHEN THE FILTER PUMP IS OFF.
Fig. 12
common terminal
Normally open terminal.
Fig. 14