4. Jumper Connections
4.1 Caution: Be sure of line voltage before
connecting the ClearO3 to the power
source. Connecting the ClearO3 to the
incorrect voltage can cause damage
to the unit. Connect green ground wire
to the time clock ground bar (Fig. 6A).
The Clear O3® unit is set to 240VAC
to be connected to the load side (Fig.
6B) of the filtration pump time clock.
4.2 The ballast may be switched to 120VAC
if the line voltage is 110VAC (Fig. 7A).
4.3 Move the jumper from the 220VAC
pins to the 110VAC pins (Fig. 7B).
4.4 If you do not have a terminal board and the
inside electrical connections look like (Fig.
8) contact Paramount for instructions on
how to change the voltage.
Fig. 5A
Fig. 5B
Ground Lug
Fig. 6A
Fig. 6A – Wiring connections
to be made inside time clock
or electrical panel.
Fig. 6B
Fig. 6B – Wiring connections
to be made inside time clock
or electrical panel.
Fig. 8
Fig. 7B
110V
Fig. 7A
220V