10
9. Use the external ground lug to
connect the ClearO3 to the pool
pump bond wire. (Fig. 15)
10. Turn on power to the filtration
system pump. Check the glow
tube on the left front of the
ClearO3. (Fig. 16) A light blue light
indicates the lamp is lit and the unit
should be producing ozone.
NOTE: IF YOU SEE A RED OF
YELLOW LIGHT THRU THE GLOW
TUBE TURN OFF THE POWER
IMMEDIATELY AND REPLACE THE
LAMP. RUNNING THE UNIT WITH
A YELLOW OR RED LIGHT WILL
DAMAGE THE BALLAST.
WARNING:
UV light produced by this unit is harmful to the eyes and may cause
blindness! Do not look directly at a lit bulb!
Fig. 15
Ground Lug
Fig. 16
Light Blue Glow Tube
1. Turn off power to the filtration
system pump at the circuit breaker.
2. Pump strainer pot installation: (Fig. 17)
2.1 Check pump elevation above
water level. Refer to (Chart
1)for proper check valve
selection. The 0.5 lb valve
comes standard with Clear
O3® and others are available
to order separately.
2.2 Remove strainer pot plug. If
there is an O-Ring on plug
take O-Ring off of pot plug
and slide over threaded end of
check valve.
Fig. 17
MAKING PLUMBING CONNECTIONS
Chart 1
Pump Elevation
Above Water Level
Check Valve
Rating
Part Numbers
1' (30cm)
0.5 lb
005-402-1250-00
2' (60cm)
1.5 lb
005-402-2502-00
4' (120cm)
3.0 lb
005-401-2503-00
5' (150cm)
4.0 lb
005-401-2504-00