Содержание PM-30 Series

Страница 1: ...1 Universal Operating Table PM 30series Instruction Manual PM 3030 PM 3130 PT PARAMOUNT BED INDONESIA lease use after sales service and inspection Keep this manual...

Страница 2: ...a long time please read and understand the operation procedures and precautions in this Instruction Manual before use After reading this instruction manual store it where it can be easily accessed fo...

Страница 3: ...g Setting the Remote Controller Setting the Power Supply Cable Operation of Main Power Supply Turning the Power Supply OFF 3 Turning the Power Supply OFF 14 Main Unit Fixture Adjustment of the Brake S...

Страница 4: ...ing the Leg section bases Opening the Leg section bases To Lower 19 To Elevate To Remove Adjustment of the Leg section base Clamp 7 Reversing Attachment Operation of the Head section base and the Leg...

Страница 5: ...When installed at the desired position remove the belt attached to the operating table When the operating table is installed in the operating room immediately perform a test operation in each section...

Страница 6: ...tient will not slide off the operating table due to is reclining bending 2 Secure the Head section base and foot plates which are removable from the operating table main unit 3 Avoid loading the whole...

Страница 7: ...of both the system and the patient 2 If any anomalies are found in the system or patient take appropriate actions such as stopping the operation of this product while ensuring the safety of the patien...

Страница 8: ...Leg section base opening handle 15 Base Mount 4 Leg section base 10 Leg section base elevation trigger 16 Remote Controller 5 Knob screw for leg section base attachment 11 Head section base angle adj...

Страница 9: ...nd the leg section base expands the application range of surgical operations 6 Fixing and moving operations can be performed using the electric motor 7 The built in remote controller can be used in th...

Страница 10: ...base and leg section base are interchangeable V Jack operation Reverse trendelenburg with the head upward and the back section base elevation operate simultaneously Jack Knife operation Trendelenburg...

Страница 11: ...ig 3 at the insertion ring into the control box connector insertion opening of the main unit Fig 2 with the groove facing upward 3 Setting the Power supply Cable Fig Power supply inlet Securely hold t...

Страница 12: ...he power supply plug Fig 4 from the power supply outlet for medical purposes in the operating room Note When removing the power supply plug from the power supply outlet hold the outlet with one hand a...

Страница 13: ...he clearance between the operation table and the floor by turning another lever handle screw When break rubber base makes contact with the floor it becomes difficult to turn the lever handle screw Mak...

Страница 14: ...y while the switch is pressed Elevation stops when the switch is released Trendelenburg Operation Press switch to reverse trendelenburg Press switch to trendelenburg Lateral Tile Operation Press switc...

Страница 15: ...termined in stages of 22 5 in the range of 2 stages upward to 45 and 4 stages downward to 90 1 To Elevate 1 Hold the edge of the head section base and pull upward without pulling the lever 2 The upwar...

Страница 16: ...ection base may fall if the fixing screw is not securely tightened Insert the head section base to the specified position as described in 3 1 3 To attach the head section base at the edge of the hip s...

Страница 17: ...e of 90 downward and can be spread over a range of 110 from side to side 1 Attaching the leg section base Loosen the knob screw insert the leg section base shaft into the opening on the hip section ba...

Страница 18: ...y turning twice and then pull the leg section base out frontward to remove holding the leg section base edge with one hand and the part labeled with the other hand Note 1 Operate with the sections and...

Страница 19: ...reversing attachment trendelenburg lateral tilt sliding and the operation direction are reversed Take care with this operation If the reversing connector which is supplied as an option is set to the b...

Страница 20: ...OFF and remove the remote controller plug before cleaning 3 Avoid cleaning the operating table main unit with water 4 Wipe first with a damp cloth and then wipe with a dry soft cloth 5 Do not leave b...

Страница 21: ...nnect the power supply cable and check that the pilot lamp goes out One AC type 5A fuses are placed inside the leg mount of the body Note Fuses must be replaced by a specialist How to Remove the Leg M...

Страница 22: ...ment Fuse Replacement Fuses Used AC Specification Two 10A fuses AC primary side One 5A fuses DC secondary side Two 10A fuses Fig Note Please replace with the correct fuses as marked on the holders A f...

Страница 23: ...4 Is the remote controller power supply ON Note OFF in 10 seconds 5 Is the operating table fixed securely If there are anomalies even when the above inspections are made please contact our service per...

Страница 24: ...24 2022 08...