A539 

 

 

 

• Educate all personnel on proper procedures to follow if a grease fire should occur. DO NOT USE 

WATER ON A GREASE FIRE! Never direct the extinguisher in a manner that would blow grease out of the 
tank. Ensure a fire extinguisher is readily available to extinguish a grease, oil, and electric fire. Make sure 
all personnel are properly trained in the use of the fire extinguisher. 
 

OPERATING INSTRUCTIONS (

Controls and Their Functions)

 

 

MAIN POWER SWITCH  

 
The 

“Red

/Yellow

” knob

 is the ON/OFF power switch which mounted on the head at the top left corner 

of the control panel.   

 

To turn unit ON, you must first unlock the knob clicking the yellow switch at the top of the red know 
from left to right.  Once unlocked, rotate the knob CLOCKWISE and it will release into the operating 
position.  On the digital display models (Models:  9125 and 9130), the digital display will light up and 
serve as your visual que that the fryer is ON.  When operating the non-digital displays (Models 9130 and 
9135), a green LED to the right of the red and yellow know will illuminate when the fryer is switch ON.   

 
DIGITAL MODELS (Model: 9120 and 9125) 
 

The digital display displays the temperature of the cooking oil. The control will display the temperature 
as long as the main power to the head is on. The digital display serves as a temperature display and as a 
reset button should the fryer encounter and issue or a tripped fuse or become overheated.  The fryer 
has a high limit control inside the control head that will power-off the unit if the fryer overheats, 
malfunctions or encounters a power surge from the blow circuit breaker.  Once the fryer cools down, 
the fryer can be reset by pushing the reset button (RST Button) on the side of the digital display.   
 

NON-DIGITAL MODELS (Model: 9130 and 9135) 
 

The non-digital display models utilize a manual thermometer (included with your fryer) to measure the 
temperature of the oil.  The fryer has a high limit control inside the control head that will power-off the 
unit if the fryer overheats, malfunctions or encounters a power surge from the blow circuit breaker.  
Once the fryer cools down, the fryer can be reset by pushing the small red reset button on the right side 
of the green LED.   
 

TEMPERATURE CONTROL KNOB 

 
To adjust and set temperature on all Paragon fryer models, use the black heat control knob on the right 
side of the fryer. Simply turn the knob CLOCKWISE to the desired temperature setting for your food 
item.   

 
DRAIN VALVE/DRAIN PLUG  
 

The Drain Valve and Drain Plug open to allow efficient draining of the cooking oil from the tank. Always 
allow hot cooking oil to cool below 140°F before attempting drain the unit. Note: The Drain Valve has a 
Safety Collar on the handle. Slide the collar up to allow the drain valve handle to be rotated. Installation

 

Содержание 9120

Страница 1: ...agon International Inc 731 W 18th Street P O Box 560 Nevada IA 50201 USA Phone 515 382 8000 Toll free 800 433 0333 Fax 515 382 8001 Email info manufacturedfun com Model Numbers 9120 9125 9130 9135 Digital 240V 4400W Non Digital 240V 4400W Digital 120V 1800W Non Digital 120V 1800W ...

Страница 2: ...ssistance Model No Serial No Voltage Business Hours 8 00 AM to 5 00 PM Central Standard Time CST Telephone 515 382 8000 800 433 0333 Email info manufacturedfun com Fax 515 382 8001 Additional information can be found by visiting our web site at www manufacturedfun com Register your unit Completing online warranty registration will prevent delay in obtaining warranty coverage Go to www manufactured...

Страница 3: ... cleaning or serving to prevent electrical shock Always wear safety glasses when servicing equipment No direct contact to equipment by the general public should be allowed when used in food service locations Only trained personnel should operate this equipment Carefully read any through this manual before beginning operation of the equipment Never make alteration to this equipment Any alterations ...

Страница 4: ...at Digital temperature display on models 9120 and 9130 High limit shutdown Designed and assembled in the USA with select foreign parts Specifications Model No Volts Watts Amps Power Plug Type Oil Capacity 9120 240 4400 20 NEMA Style 6 20P 25 lbs 9125 240 4400 20 NEMA Style 6 20P 25 lbs 9130 110 1800 20 NEMA Style 5 15P 25 lbs 9135 110 1800 20 NEMA Style 5 15P 25 lbs Should you have any questions a...

Страница 5: ...al thermometer can be inserted and monitored without reaching over the tank 5 After setup the unit should be cleaned prior to use see Care and Cleaning section of this manual Electrical Requirements The following power supply must be provided Models 9120 and 9125 require the following power supply 20 Amp 6 20 Receptacle 60 Hz Models 9130 and 9135 require the following power supply 20 Amp 6 20 Rece...

Страница 6: ...and a temperature control knob Paragon utilizes the highest quality controls available in its this product However in time all controls wear out It is therefore recommended an independent thermometer capable of 500 F or higher be immersed in the oil to monitor the oil temperature and make sure the unit is operating properly DANGER Hot oil is dangerous severe burns can result when hot oil contacts ...

Страница 7: ... serves as a temperature display and as a reset button should the fryer encounter and issue or a tripped fuse or become overheated The fryer has a high limit control inside the control head that will power off the unit if the fryer overheats malfunctions or encounters a power surge from the blow circuit breaker Once the fryer cools down the fryer can be reset by pushing the reset button RST Button...

Страница 8: ...ch off The heating element should be hot Test is completed the fryer is now ready for use WARNING Do not operate without any cooking oil Note If digital display unit buttons accidentally get pushed causing the unit to display unknown readings simply turn the Master Switch off then back on Please proceed with Step 1 as listed above Operation 1 Be sure the drain valve is closed 2 Fill the fryer tank...

Страница 9: ...on and Quality Control Tips Don t overheat Don t fry if the oil temperature exceeds 400 F Don t fry food in broken down frying shortening Broken down oil is thinned darkened Don t overload the frying tank Don t fill the basket more than half full Don t shake breaded items over fryer Don t salt items over fryer Don t introduce water to fryer Don t thaw frozen foods before frying Operating the Fryer...

Страница 10: ... fully tightened into place then fill the tank with water to the MINIMUM oil level DO NOT FILL above the minimum oil level or equipment damage may occur 4 Add appropriate amount of dish soap Paragon also recommend the use of Carbon Off Cleaner 5 Bring solution to a boil DO NOT heat above 250 F then turn the fryer OFF unplug the unit and allow solution to cool to below 100 F 6 Once cooled drain and...

Страница 11: ...A539 6 CABINET ASSEMBLY Cabinet and Oil Tank Valve Fryer Cover Control Head ...

Страница 12: ...Thermostat Bulb 78280 Heating Element 78100 Thermo Limit Probe 78005 Power Switch On Off 12420 Digital Temperature Display 78001 Thermostat Knob HDS_0036 Relay 78210 Power Cord 12176 Digital Display Master ON OFF Switch Digital Reset Button Thermostat Knob Heating Element Thermo Limit Probe ...

Страница 13: ...280 Heating Element 78100 Thermo Limit Probe 78005 Thermostat Hi Limit 78002 Power Switch On Off 12420 Reset Button 78001 Thermostat Knob HDS_0036 Relay 78210 LED Green Lamp 98540 Power Cord 12176 Thermostat Knob Master ON OFF Switch Manual Reset Button Thermo Limit Probe Thermostat Bulb Heating Element LED ...

Страница 14: ...A539 WIRING DIAGRAM FOR MODELS 9120 ...

Страница 15: ...A539 WIRING DIAGRAM FOR MODELS 9120 ...

Страница 16: ...A539 WIRING DIAGRAM FOR MODELS 9155 AND 9135 ...

Страница 17: ...A539 ...

Отзывы: