Setting Up Service Provider Connectivity at the
Central Site
When management needs to be set up between a service provider’s customer and its
network operations center (NOC), a non-multiplexed DLCI must be configured to carry
management data between the customer’s central site and the NOC console. This
requires that a frame relay discovered DLCI needs to be modified. This is because all
auto-configured network DLCIs are configured as multiplexed DLCIs.
Procedure
To set up NOC management:
1.
Select DLCI Records on the network interface:
Configuration
→
Network
→
DLCI Records
2.
Select Modify. The
Modify DLCI Record for DLCI Number?
prompt appears.
3.
Select the DLCI that will be used by pressing the spacebar until the correct DLCI
number appears, then select it.
4.
Change the DLCI Type from Multiplexed to Standard.
The
DLCI in connections
.
Update DLCI usage as follows:
prompt
appears.
5.
Select the
Delete EDLCI Connections and Make a Mgmt Only PVC
option.
PVC connections for the selected DLCI are broken, the Port-1 DLCI mapped to this
network DLCI and the embedded management DLCI (EDLCI) are deleted, and the
selected DLCI will be reconfigured as a management PVC using the Node IP
Address.
Configuring SNMP Trap Managers and Traps
Once the iMarc unit is connected to the network, SNMP trap managers and SNMP traps
can be configured.
Procedure
To enter SNMP managers and configure traps:
1.
Select SNMP Traps.
Main Menu
→
Configuration
→
Management and Communication
→
SNMP Traps
2.
Configure the following:
—
Enable SNMP Traps.
—
Identify the total Number of Trap Managers.
—
Specify the IP address of the NMS(s) to which traps will be sent.
—
Specify the network Destination for the Trap Manager(s).
—
Select desired trap categories.