Setting Up a Management PVC to the NOC
Management between the FrameSaver NNI unit and the service provider’s network
operations or control center (NOC or NCC) needs to be set up. A non-multiplexed DLCI
must be configured to carry management data between the FrameSaver NNI unit and
the NOC console.
To set up NOC management:
1. Select DLCI Records on the network interface:
Configuration Edit/Display
→
Network
→
DLCI Records
2. Type o (Modify) and press Enter. The Modify DLCI Record for DLCI Number?
prompt will appear.
3. Select the DLCI that will be used
by
pressing the spacebar until the correct DLCI
number appears, then press Enter.
4. With the cursor on the DLCI Type field, press the spacebar to change the DLCI
Type from Multiplexed to Standard.
The Delete EDLCI Connections and Make it a Mgmt Only PVC? prompt
appears.
5. Type y for yes and press Enter.
PVC connections for the selected DLCI are broken, the Port-1 DLCI mapped to
this network DLCI and the embedded management DLCI (EDLCI) are deleted, and
the selected DLCI will be reconfigured as a management PVC.