Using NetScout Manager Plus
6-8
June 1999 - Preliminary
Adding SLV Alarms Using a Template
Once DLCIs have been discovered, SLV alarms should be configured and
assigned to each DLCI. Paradyne provides a template for configuring alarms.
DLCI alarms can be configured manually, but using the Paradyne alarm defaults
template greatly reduces configuration time.
The following alarms are configured for each DLCI included in the Paradyne MIB:
— Frames Sent (SLVFramesSnt)
— Rx DLCI Utilization (SLVrxDLCIUtil)
— Tx CIR Utilization (SLVTxCIRUtil)
— Frames Sent Above CIR
(SLVFramesTxAbvCIR)
— Tx DLCI Utilization (SLVTxDLCIUtil)
— Average Latency (AverageLatency)
— Frames Received (SLVFramesRec)
— Current Latency (CurrentLatency)
These alarms and current values can be found in $NSHOME/usr/slvtemplate.fct,
which is used as a starting point for loading new alarms. This file can be copied
and edited so the alarm threshold values match service level agreement values.
The copied .fct file can then be used to replicate alarm threshold values for all
DLCIs on the unit using the eztrap utility. All .fct files must be in $NSHOME/usr.
To configure alarms manually, see
Adding SLV Alarms Manually
on page 6-11.
NOTE:
Perl must be installed in your system to use the eztrap utility in the procedure
below. If you have an NT system, please install Perl before proceeding.
"
Procedure
1. Open a terminal window and go to
$NSHOME/usr
.
2. Type
eztrap -i
filename
.fct -o
agentname
.fct
agentname and
press Enter to run the eztrap utility to create alarm threshold values across
all DLCIs for the copied .fct file.
The message
eztrap done
appears when the .fct file is transferred.
3. From the NetScout Manager Plus main window, with the FrameRelay and
Admin radio buttons still selected, click on the Config Manager icon to open
the Configuration Manager main window (see the window on
page 6-5
).
4. Edit any alarm values that need to be changed.
5. Select the Install button (down the center of the Configuration Manager
main window) to load alarms for the unit. This may take some time, so
please be patient.
See
Editing Alarms
on page 6-9 if any default settings need to be changed.
Содержание FrameSaver SLV 9124
Страница 1: ...FrameSaverr SLV 9124 TECHNICAL REFERENCE Document No 9124 A2 GH30 00 June 1999 PRELIMINARY DRAFT ...
Страница 22: ...About the FrameSaver SLV 1 8 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 200: ...Configuration 8 78 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 286: ...Menu Hierarchy A 4 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 330: ...Cables Connectors and Pin Assignments D 10 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 346: ...Index IN 12 9124 A2 GH30 00 June 1999 This page intentionally left blank ...