Troubleshooting
11-29
9124-A2-GH30-00
June 1999 - Preliminary
Lamp Test
The
FrameSaver unit supports a Lamp Test to verify that all LEDs are lighting and
functioning properly. All LEDs flash or blink on and off at the same time every 1/2
second during execution of the test. When the test is stopped, the LEDs are
restored to their normal condition.
If the Test Timeout configuration option is enabled and a Test Duration is set, the
Lamp Test stops when the test duration expires.
See
Configuring General System Options
in Chapter 8,
Configuration Options, to
configure the unit to stop the test automatically.
"
Procedure
To perform a Lamp Test from DCE Manager, take the folllowing path:
DCE Manager
→
Device Display
→
Diagnosis menu
→
Lamp Test Start
The LEDs on the unit start blinking. Once the device is located and the LEDs
verified, select Lamp Test Stop. The unit LEDs return to normal operation.
"
Procedure
To perform a Lamp Test from Performance Wizard:
1. Click on the Tests button from Navigation Wizard.
2. Highlight the unit to be tested.
3. Click on the Device Tests menu and select Start Lamp Test.
4. To stop the test, select Stop Lamp Test from the Device Tests menu.
Содержание FrameSaver SLV 9124
Страница 1: ...FrameSaverr SLV 9124 TECHNICAL REFERENCE Document No 9124 A2 GH30 00 June 1999 PRELIMINARY DRAFT ...
Страница 22: ...About the FrameSaver SLV 1 8 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 200: ...Configuration 8 78 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 286: ...Menu Hierarchy A 4 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 330: ...Cables Connectors and Pin Assignments D 10 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 346: ...Index IN 12 9124 A2 GH30 00 June 1999 This page intentionally left blank ...