Operation and Maintenance
10-18
9124-A2-GH30-00
June 1999 - Preliminary
Table 10-6.
Health and Status Messages (6 of 6)
Message
What To Do
What It Indicates
Yellow at Network n
A yellow alarm signal is
received on the specified
network interface.
1. Network cable problem.
2. T1 facility problem.
1. Check that your network cable
is securely attached at both
ends.
2. Contact your network provider.
1
Record the failure code before resetting the FrameSaver unit; otherwise, the error
information will be lost.
Test Status Messages
These test messages appear in the right column of the System and Test Status
screen.
You have the option of allowing the test to continue or aborting the test. Refer to
Chapter 13,
Troubleshooting
, for more information on tests, including how to start
and stop them.
Table 10-7.
Test Status Messages (1 of 2)
Message
What It Indicates
DCLB Active, Port-1 or
frame relay link
A Data Channel Loopback is active on the data
port or a T1 frame relay link.
DTE External LB Active, Port-1
An external DTE Loopback is running on the
specified port.
DTE Init. Ext LB Active, Port-1
DTE has initiated an external DTE Loopback on
the specified port.
FCC Test Active
Should never see this message.
Lamp Test Active
The Lamp Test is active, causing the LEDs on the
faceplate to flash on and off.
Monitor Pttn Active, DLCI nnnn,
frame_relay_link
1, 2
FrameSaver unit is monitoring a test pattern on the
specified DLCI on the specified frame relay link.
Monitor Pttn Active, [interface]
FrameSaver unit is monitoring the selected test
pattern on the specified interface.
LLB Active, DSX-1
LLB Active, Network
A Line Loopback (LLB) test is active on the
specified network interface.
PLB Active, DSX-1
PLB Active, Network
A Payload Loopback (PLB) test is active on the
specified network interface.
Содержание FrameSaver SLV 9124
Страница 1: ...FrameSaverr SLV 9124 TECHNICAL REFERENCE Document No 9124 A2 GH30 00 June 1999 PRELIMINARY DRAFT ...
Страница 22: ...About the FrameSaver SLV 1 8 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 200: ...Configuration 8 78 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 286: ...Menu Hierarchy A 4 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 330: ...Cables Connectors and Pin Assignments D 10 9124 A2 GH30 00 June 1999 Preliminary This page intentionally left blank ...
Страница 346: ...Index IN 12 9124 A2 GH30 00 June 1999 This page intentionally left blank ...